3.1
CONTROL PANEL (fig. 14)
3 CHARACTERISTICS
5
3
1
2
4
Fig..14
47
IT
ENG
RUS
WARNING: The SUMMER mode is activated only when the
boiler is connected to an external water heater ACS.
2 - DESCRIPTION OF CONTROLS
5
3
1
2
4
ON/OFF KEYS
ON.=.. Electricity.supply.to.boiler.is.on
OFF.=..
Electricity. supply. to. boiler. is. on. but. nor.
ready. for. functioning.. However,. the. protec-
tion.functions.are.active.
5
3
1
2
4
SUMMER MODE KEY
When.this.key.is.pressed,.the.boiler.functions.only.
when.D.H.W..is.requested.
5
3
1
2
4
WINTER MODE KEY
When.this.key.is.pressed,.the.boiler.provides.hea-
ting.and.D.H.W.
5
3
1
2
4
D.H.W. TEMP KEY
When. this. key. is. pressed,. the. temperature. of. the.
D.H.W..is.shown.on.the.display.
5
3
1
2
4
HEATING TEMP KEY
The.first.time.the.key.is.pressed,.the.temperature.of.
heating.circuit.1.is.shown.
The.second.time.the.key.is.pressed,.the.temperatu-
re.of.heating.circuit.2.is.shown.
5
3
1
2
4
RE-SET KEY
This.allows.for.restoring.functioning.after.a.functio-
ning.anomaly.
5
3
1
2
4
INCREASE AND DECREASE KEY
By. pressing. this. key. the. set. value. increases. or.
decreases.
4 -
LUMINOUS BAR
. Blue.=.Functioning
. Red.=.Functioning.anomaly
5 - PROGRAMMING CLOCK (optional)
Mechanical. clock. (code. 8092228). or. digital. clock.
(code.8092229).to.program.heating.and.water.supply.
3 - KEYS RESERVED FOR THE INSTALLER
(access to INST and OEM parameters)
PC CONNECTION
To.be.used.only.with.the.SIME.programming.kit.and.only.by.
authorised.personnel..Do.not.connect.other.electronic.devi-
ces. (cameras,. telephones,. mp3. players,. etc.). Use. a. tool. to.
remove.the.cap.and.reinsert.after.use.
ATTENTION: Communication port
sensitive to electrostatic charges.
Before. use,. it. is. advisable. to. touch. an.
earthed.metallic.surface.to.discharge.static.electricity.
INFORMATION KEY
This. key. can. be. pressed. several. times. to. view. the.
parameters.
.
CHIMNEY SWEEP KEY
This. key. can. be. pressed. several. times. to. view. the.
parameters..
DECREASE KEY
This.key.changes.the.default.settings.
INCREASE KEY
This.key.changes.the.default.settings.
5
3
1
2
4
DESCRIPTION OF DISPLAY ICONS
SUMMER MODE ICON
WINTER MODE ICON
D.H.W. MODE ICON
HEATING MODE ICON
1.=.First.circuit.heating.system
2.=.Second.circuit.heating.system
GRADED POWER SCALE
The. segments. of. the. bar. light. up. in. proportion. to. boiler.
power.output..
BURNER FUNCTIONING AND BLOCK ICON
DESCRIPTION OF DISPLAY ICONS
CHIMNEY SWEEP ICON
SECONDARY DIGITS
The.boiler.visualises.the.value.of.the.pressure.of.the.
system.(correct.value.is.between.1.and.1.5.bar)
MAIN DIGITS
The.boiler.visualises.the.values.set,.the.state.of.ano-
maly.and.the.external.temperature
INTEGRATIVE SOURCES ICON
Summary of Contents for RX 19 E
Page 2: ......
Page 32: ...32 NOTES...
Page 62: ...62 NOTES...
Page 63: ...1 64 2 68 3 77 4 84 RX E Fonderie Sime S p A RX E 92 42 CEE 2009 142 CE 2014 30 UE 2014 35 UE...
Page 83: ...3 8 P 17 5 RX 37 48 55 E 12 5 12 83 IT ENG RUS 5 1 2 3 4 17 16 1 2 3 1 2 12 3 4 12 5...
Page 92: ...92 NOTES...
Page 93: ...93 IT ENG RUS NOTES...
Page 94: ...94 NOTES...
Page 95: ......