Open the gas valve, lower the control panel

cover and activate the boiler by rotating the

selector knob to the summer positio (

). 

The  lighting-up  of  the  green  led (

)  will

indicate that the apparatus is switched-on

and ready.

Once  the  boiler  has  reached  the  value  set

on the heating potentiometer, it will start to

modulate in automatically in order to supply

the  required  power  output  to  the  system.

The  operation  of  the  boiler  will  be  stopped

through the intervention of the thermostat

or “Logica Remote Control”.

TURNING THE 

BOILER OFF  

(fig. 1)

To  turn  the  boiler  off  place  the  selector

knob on the 

OFF 

position. 

If  the  boiler  is  not  going  to  be  used    for  a

lengthy  period  it  is  advised  to  turn  off  the

electricity  supply,  close  the  gas  tap,  and  if

the  temperatures  foreseen  are  low,  empty

the boiler and the hydraulic system to avoid

breakage in the tubes due to the freezing of

the water.

C.H. TEMPERATURE

ADJUSTMENT

(fig. 2)

The  C.H.  temperature  can  be  adjusted  by

turning  the  knob  of  the  C.H.  potentiometer

(

).  The  set  temperature  is  indicated  on

the  red  led  scale  from  35÷80°C  and  the

yellow  heating  led  lights  up  at  the  same

time (

). 

If the temperature of the C.H. return water

is  lower  than  around  55° C,  condensation

of  the  combustion  by-products  is  obtained,

further  increasing  the  efficency  of  thew

thermal exchange.

USER INSTRUCTIONS

WARNINGS

– In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking any direct

action. Contact an authorised technical staff.

– The installation of the boiler and any servicing or maintenance job must be carried out by qualified personnel. Under

no circumstances, the devices sealed by the manufacturer can be tampered with.

– It  is  absolutely  prohibited  to  block  the  intake  grilles  and  the  aeration  opening  of  the  room  where  the  equipment  is

installed.

LIGHTING AND OPERATION

R

E

M

O

T

E

C O N T R O L

R

APRE

SPIA VERDE

Fig. 1

SPIA GIALLA

SPIA ROSSA

Fig. 2

GREEN LED

OPEN

RED LED

YELLOW LED

Summary of Contents for PLANET DEWY 30 BFR

Page 1: ...is unobstructed and has been pro perly installed Make sure that any shutoff valves are open Make sure that the system is charged with water and is thoroughly vented Check that the circulating pump is...

Page 2: ...H return 3 4 M C H flow 3 4 G Gas connection 3 4 C1 System filling optional 1 2 S3 Condensation outlet 25 1 3 TECHNICAL FEATURES 30 BFR Heat output Nominal 80 60 C kW kcal h 28 3 24 300 Minimum 80 60...

Page 3: ...ixing jig 19 90 C limit stat 20 Condensation water trap 21 Gas rate adjuster 22 System filling optional 23 Aqua Guard 24 Non return valve 1 5 MAIN COMPONENTS Fig 3 KEY 1 Control panel 2 Gas rate adjus...

Page 4: ...e data plate is sticked inside the front panel it contains all the technical data identifying the boiler and the type of gas for which the boiler is arranged 2 3 1 Connection of condensation water tra...

Page 5: ...ow eaves 300 D below balcony 1 300 E from adjacent window 400 F from adjacent ventilation opening 600 G from horizontal or vertical soil or drain pipes 2 300 H from corner of building 300 I from reces...

Page 6: ...on calculation in that the sum of the head losses of the single fittings is less than 15 5 mm H2O Inlet Outlet 7 m horizontal pipe 80 x 0 20 1 40 7 m horizontal pipe 80 x 0 30 2 10 n 2 90 elbows 80 x...

Page 7: ...eed 15 5 mm H2O When calculating the lengths of pipe take into account the parameters given in the Table 2 2 8 60 PIPING SYSTEM A special kit allows to separate smoke outlet and air intake pipes The 8...

Page 8: ...cables of section 0 5 mm2 First of all assemble and wire the socket 2 then insert the equipment which will start up as soon as it receives current To gain access to connector 3 remove the control pan...

Page 9: ...electrode ER Sensing electrode TS 100 C safety stat V Fan TPA Water pressure transducer P Pump SE External sensor optional TA Room stat SM C H sensor blue TR Transformer 230 24V FL Flowmeter CR Logic...

Page 10: ...rough a window contact Anti bacterial 2 10 1 Installation The unit must be installed in the main living room For installation follow the assembly instructions inserted in the package At this point wit...

Page 11: ...nute of the prescribed delivery temperature value sent in C is limited to the imposed value With the activation of the adaptation the pre set value transmitted to the boiler regulator is adapted to th...

Page 12: ...o par metro 64 1 0 activa s a sonda interna 0 externa 100 interna 50 valor m dio da sonda externa interna 100 activa s a sonda externa Para a regula o ambiente e a visualiza o utilizada a mistura pro...

Page 13: ...egulated so as to obtain a pressure of approx 3 mbar at the burner for methane gas and 7 mbar for propane gas G31 To increase pressure turn the trimmer clockwise to reduce pres sure turn the trimmer c...

Page 14: ...up There could have a break in the wire of the sensing electrode or the electrode itself is touching earth the electrode is worn out and needs replacing The con trol box is defective When there is a...

Page 15: ...function of the flow in graph in fig 21 3 7 MAINS ELECTRICITY CONNECTION Use a separate electricity supply to con nect the room stats and relative zone val ves or pumps The micro or relay contact con...

Page 16: ...2 Gas valve 3 Mixer intake 4 Ventilator intake 5 Nozzle 6 Fan 7 Air gas mixer 8 Air pressure switch 9 Digital pressure gauge Fig 24 0 30 20 10 p aria mm H2O Potenza termica kW 25 20 10 15 50 40 60 5 3...

Page 17: ...G31 boilers it is a good idea to check that the position of the GPL bridge on the control board is correct Diaphragm code 6028640 Drawing 7 is assembled on the Dewy 25 model functioning on PROPANE G3...

Page 18: ...sliding them out of their slots 4 6 CLEANING AND MAINTENANCE Preventive maintenance and checking of efficient operation of equipment and safety devices must be carried out exclusively by authorized te...

Page 19: ...ing of the water C H TEMPERATURE ADJUSTMENT fig 2 The C H temperature can be adjusted by turning the knob of the C H potentiometer The set temperature is indicated on the red led scale from 35 80 C an...

Page 20: ...out occurs again call local authorised Service Centre for technical assistance Other anomalies fig 6 When one of the red 40 80 C leds start flashing switch off the boiler and then try to ignite again...

Page 21: ...utton automatic operation 4 Operating mode button manual operation 5 Operating mode button availability 6 Cover with instruction compartment 7 Temperature knob 8 Presence button Fig 8 KEY 1 Display ti...

Page 22: ...l lowing list of items one after the other are displayed The thermo feeler continues to function independently of the display Day hour room temperature External temperature Hot water service temperatu...

Page 23: ...ity boiler unit temperature desired for hot water service at reduced level To have access to the reduced hot water service temperature parameter press the and keys at the same time for at least 5 seco...

Page 24: ...rature set in parameter 3 1 standard Hot water according to the daily heating programme In the comfort periods of the heating the temperature of the boiler unit is regulated at the value set via para...

Page 25: ...of the heating characteristics curve When the room temperature set is not reached choose the gradient indicated in point 2 9 3 Display of the current boiler temperature Display of the current power of...

Page 26: ...fficient water pressure Reset operation using the boiler charge valve fig 4 Plant overpressure Call an authorised Service Centre Safety thermostat trips Call an authorised Service Centre Fan air press...

Reviews: