52
6.3.4
Navigating using the MENU button
CONFIRM REQUEST
a
Confirm operation?
CONFIRM REQUEST
a
Confirm operation?
CONFIRM REQUEST
a
Confirm operation?
RESET ALARM HISTORY
HEAT PUMP
Battery temp.
25.3°C
Input water temp.
28.6°C
Output water temp.
28.8°C
Fan speed %
0%
Compr. bypass valve
ON
Compressor
OFF
Defrosting phase
OFF
Compr. op. hrs.
51h
Defrosting
OFF
INFORMATION
Zone heating
[...]
Heat pump
[...]
Boiler
[...]
Hot water
[...]
Solar thermal
[...]
Alarms
[...]
Firmware version
100
(These screens are for display only. Modifying data is NOT possible)
HT-BOILER ADJUST. PARAM.
P 110
P 120
P 130
P 140
P 150
P 160
P 170
P 180
P 190
P 510
P 520
P 530
P 540
P 550
Time Programming
ADVANCED PARAMETERS HT
No. interv. press.
TECHNICAL
STATE HYBRID OPERATION
State hybrid operation [...]
Zone heating
[...]
Ht-boiler adjust. param. [...]
Hot water
[...]
Boiler parameters
[...]
Advanced parameters Ht [...]
Reset alarm history
[...]
Factory total reset
[...]
Customer service
[...]
Heat req..
0
Heating set
°C
Heating temp.
°C
Return temperature
°C
Burner power
%
HP deliv. set
°C
Output water temp.
°C
Compressor
OFF
Fan speed
%
Battery temp.
°C
Defrosting
OFF
Ext. temp.
°C
On time
min
MENU
GENERAL SETTINGS
[...]
INFORMATION
[...]
TECHNICAL
[...]
Modo: Inverno Progr. automatico - Set 18,0 Cfino alle 11:30
Menu
Modo
VISUALIZATION
Contrast
10
Lighting display
34
Lighting knob
ON
MENU
MENU
GENERAL SETTINGS
[...]
INFORMATION
[...]
TECHNICAL
[...]
GENERAL SETTINGS
Language
[...]
Date and time
[...]
Visualization
[...]
Factory settings
[...]
ZONE HEATING
Room set 20.0°C
Heating set
0°C
Heating temp.
28.0°C
BOILER
Return temperature
25.0°C
Power output
0%
System pressure
1.2bar
Exhaust temp.
_ _ _°C
CONFIRM REQUEST
a
Confirm operation?
[CONFIRM]
TECHNICAL
click
To “select” rows or “modify” values
To “confirm” the selections or modifications
HOT WATER
Hot water temp
51.2C
Hot water set
50°C
Flow rate
--l/min
SOLAR THERMAL ENERGY
Temp. gas manifold 1
_ _°C
Temp. storage tank 1
_ _°C
Temp. gas manifold 2
_ _°C
Temp. storage tank 2
_ _°C
Solar pump
_ _%
Instant power
_ _kW
ALARM HISTORY
Historical index:
1
1 -------- 5
< last
Alarm code: 5
CUSTOMER SERVICE
Name: xxxxxxxxxx
Phone: yyyyyyyyyyy
ZONE HEATING
Room probe run
YES
Room probe modul.
YES
Ext. probe modul.
YES
Weather comp.curve
3.0
Weather comp. offset
0°C
Backlash off temp.
0.1°C
System inertia
10
Flow temp.min. set
20°C
Antifreeze enable
YES
Antifreeze set
5.0°C
Room probe offset
0.0°C
HOT WATER
Enable anti-legionella function NO
Day of the intervention
Mo
Time of the intervention
02:00
CUSTOMER SERVICE
Name: xxxxxxxxxx
Phone: yyyyyyyyyyy
BOILER PARAMETERS
1...49
Parameter index
1
Parameter value
_ _
BOILER PARAMETERS
ENTER ACCESS CODE
Code:
0
0 0 0 0
[CONFIRM]
(The “Hybrid function status” is
read-only.)
Rich da TA est
NO
RESTORE FACTORY SETTINGS
Fig. 142