2.12
BOILER ELECTRICAL “25-30-35 ErP” (fig. 11/a)
OP
(24 VAC)
EXP
(24 VAC)
TA2
(24 VRAC)
TA1
(24 VRAC)
SE (5 VDC)
TS (24 VDC)
TL (24 VDC)
SM (5 VDC)
SF (5 VDC)
SR (5 VDC)
TPA (5 VDC)
SS (5 VDC)
FLM (5 VDC)
ST
(5 VDC)
BIANCO-WHITE
Fig. 11/a
KEY
F1-2
Fuse (4 AT)
TRA
Ignition transformer
PI
Pump high efficiency
V
Fan
TL
Limit thermostat
EA
Ignition electrode
ER
Detection electrode
EV1-2 Gas valve coil
TS
Safety thermostat
SF
Sensor fumes
TFU
Thermal fuse
VD
Diverter valve
SM
C.H. flow sensor
SR
C.H. return sensor
SS
D.H.W. sensor
TPA
Pressure transducer
FLM
D.H.W. flowmeter
TA1
Zone 1 environment thermostat
JP1
Selection TA2 or 0-10 VDC
TA2
Zone 2 environment thermostat
ST
Solar heat sensor
CR
Remote control SIME HOME (optional)
SE
External sensor
(supplied with)
OP
Programming clock (optional)
EXP
Expansion card
AR
Remote alarm
VZ
Zone valve
AUX
Auxiliary connection
NOTE: Connect TA1 to the clamps 7-8 after
having removed the bridge.
CONNECTOR SPARE PART
CODES:
CN1/13
code 6319146
CN2
code 6323886
CN3
code 6319145
CN4
code 6316203
CN6
code 6316202
CN7
code 6316204
CN9
code 6316295
CN12
code 6316280
CN14
code 6316213
CN18
code 6319147
For the range 0 ... 10VDC:
- Remove the jumper JP1
- Connect the positive signal at terminal 10 of CN6
- Connect the negative signal at terminal 4 of the CN4.