21
2.9
BOILER ELECTRICAL
Fig. 11
KEY
F1-2
Fuse (4 AT)
TRA
Ignition transformer
PI
Pump
V
Fan
EA Ignition
electrode
ER
Ionisation electrode
EV1-2
Gas valve coil
TS
Safety thermostat
SF
Exhaust fumes sensor
TL
Limit stat
SM
Heating sensor
FL
Water flow switch
VD
Diverter valve
TPA
Pressure transducer
TA1
Zone 1 environment thermostat
TA2
Zone 2 environment thermostat
SB
D.H.W. sensor
CR
Remote control CR 73 (optional)
SE
External sensor (optional)
OP
Programming clock (optional)
EXP
Expansion card
AR/PR Recirculation pump control
or remote alarm
VZ
Zone valve
AUX
Auxiliary connection
TLS
D.H.W. over heating thermostat 85°
NOTE: Boiler heating control can be by
either voltage free switching on terminals 7
& 8 of CN 6 after removal of the link, or by
a 240 v demand on terminal 14 CN7 and
removal of the link on 7 & 8 on CN6.
A permanent power supply must be main-
tained at all times.
CONNECTOR SPARE
PART CODES:
CN1/CN13
code 6316231
CN2
code 6316233
CN3
code 6316276
CN4
code 6316203
CN5
code 6316200
CN6
code 6316202
CN7
code 6316204
CN9
code 6316201
CN10
cod. 6316227
CN11
cod. 6316226
CN12
code 6299991
CN14
code 6316230