14
163
67
286
21
1
16
6
222
336
156
130
67
CA
CA
CS
CA
CA
CS
25/55
30/55
11
5
19
0
ø 80
ø 60
2.4.7
Filter on the gas pipe
The gas valve is supplied ex factory with an
inlet filter, which, however, is not adequate
to entrap all the impurities in the gas or in
gas main pipes.
To prevent malfunctioning of the valve, or in
certain cases even to cut out the safety
device with which the valve is equipped,
install an adequate filter on the gas pipe.
2.4.8
Discharge Pipe
See fig. 6 for example discharge pipe termi-
nations.
2.5
INSTALLATION OF COAXIAL DUCT
(ø 60/100 - ø 80/125)
The axial suction and discharge pipes are
supplied in a special kit (that can be purcha-
sed separ at el y) along wit h assembl y
instructions. The diagrams of fig. 7 illustra-
te some examples of different types of
discharge modalities allowed and the maxi-
mum lengths that can be reached.
2.6
INSTALLATION OF SEPARATE
DUCTS (ø 80)
Separate duct kit code 8089911 is used to
connect twin 80mm pipes. See fig 8.
The maximum overall length of the flue is
determined by the head losses of the indivi-
dual components and must not exceed
15mm H
2
O. Additionally the length of either
the inlet or exhaust pipe must not exceed
50 m. See
Table 1
for information on the
load losses of single accessories and
Fig. 9
for types of “smoke outlet”-”air inlet”.
2.6.1
Separate ducts kit
The diagrams of Figure 9 show a few exam-
ples of the permitted exhausts configura-
tions.
Fig. 8
TABLE 1 - ACCESSORIES ø 80
Accessories ø 80
Head loss (mm H
2
O)
25/55
30/55
Inlet
Outlet
Inlet
Outlet
Coaxial duct kit
--
--
--
--
90° elbow MF
0.20
0.25
0.25
0.30
45° elbow MF
0.15
0.15
0.20
0.20
Extension L. 1000 (horizontal)
0.15
0.15
0.20
0.20
Extension L. 1000 (vertical)
0.15
0.15
0.20
0.20
Wall terminal
0.10
0.25
0.10
0.35
Wall coaxial exhaust *
Roof outlet terminal *
0.80
0.10
1.10
0.15
*
This loss includes the losses of the adaptor 8091401.
9
C
C33
11
10
3
1
1
3
3
7
3
12
12
12
LIST OF ø 80 ACCESSORIES
1
Coaxial duct kit code 8089911
2
Additional 90° MF curve code 8077450 (6 pz.)
3 a Extension L. 1000 code 8077351 (6 pz.)
3 b Extension L. 500 code 8077350 (6 pz.)
7 a Additional 45° MF curve code 8077451(6 pz.)
7 b Additional 90° MF curve code 8077450 (6 pz.)
9
Manifold, code 8091401
10
Articulated tile code 8091300
11
Roof terminal code 8091205
13
Union suction/exhaust code 8091401
14
Coaxial exhaust ø 80/125 L. 885 code 8096253A
NOTE
Before connecting accessories, it is always advisable to lubricate the internal part of
the gaskets with silicon grease. Horizontal terminals must be level.
Fig. 9
KEY
CA
Inlet
CS
Outlet
C13
3
2
3
1
14
12
13
12