2

Main burner nozzles

Pilot injector

Gas consumption (*)

BOILER MODEL

Quantity

Natural gas

G30-G31

Natural gas

G30-G31

Natural gas

L.P.G. G30

L.P.G.G31

ø mm

ø mm

ø mm

ø mm

m

3

s/h

kg/h

kg/h

MURELLE 20

13

1,30

0,75

0,25

0,20

2,72

2,02

1,99

MURELLE 25

15

1,30

0,77

-

-

3,23

2,41

2,37

MURELLE 20 BF

13

1,30

0,75

0,27

0,20

2,72

2,02

1,99

MURELLE 25 BF

15

1,30

0,77

-

-

3,47

2,58

2,54

TABLE 3

Burner gas pressure

Gas supply pressure

BOILER MODEL

Natural gas

L.P.G. (G30)

L.PG. (G31)

Natural gas

L.P.G. (G30)

L.P.G. (G31)

mbar

mbar

mbar

mbar

mbar

mbar

MURELLE 20-20 BF

10

28

35

20

30

37

MURELLE 25-25 BF

11

28

35

20

30

37

TABLE 4

NOTE:

The burner header gas pressure and inputs shown in the table refer to the boiler max. capacity. These values must be kept to
in the D.H.W. production.

(*) The gas consumptions refer to the calorific value at standard conditions at 15°C - 1013 mbar

Power

Smokes

Smokes

D.H.W.

D.H.W. flow rate 

Minimum

D.H.W. pressure

BOILER MODEL

consumption

temperature

flow

Heat Output

∆t 30°C

D.H.W. flow rate

Min.

Max.

°C

gr/s

kW

I/min

I/min

bar

bar

MURELLE 20

105 (150 vers. TX)

100

24.7

23.3

11.0

2

0.5

7

MURELLE 25

120

100

29.4

27.6

12.9

2

0.5

7

MURELLE 20 BF

150

136

17.2

23.3

11.0

2

0.5

7

MURELLE 25 BF

160

136

22.8

29.6

12.9

2

0.5

7

TABLE 2

1.4

TECHNICAL FEATURES

Heat Output 

Heat Input

Electr. protection

Maximum

Expans. vessel

Expans. vessel

Weight

BOILER MODEL

(adjustable)

(adjustable)

grade

water head

contents

preloading

kW

kW

W

bar

l

bar

Kg

MURELLE 20

9.3 ÷ 23.3

10.8 ÷ 25.7

3

7

1

40

MURELLE 25

11.6 ÷ 27.6

13.5 ÷ 30.6

3

7

1

48

MURELLE 20 BF

9.3 ÷ 23.3

10.8 ÷ 25.7

IP 44

3

7

1

48

MURELLE 25 BF

15.1 ÷ 29.6

18.0 ÷ 32.8

IP 44

3

7

1

54

TABLE 1

Summary of Contents for MURELLE 20

Page 1: ...Heating Equipment Murelle user instructions GB...

Page 2: ......

Page 3: ...DENTIFICATION 1 3 DIMENSIONS 1 4 TECHNICAL FEATURES 2 2 USE AND MAINTENANCE 2 1 BOILER IGNITION 3 2 2 LOCK OUT RESET OF ELECTRONIC EQUIPMENT 4 2 3 TURNING OFF BOILER 2 4 WATER FAILURE SAFETY DEVICE 2...

Page 4: ......

Page 5: ...25 CE IONO with electronic ignition and modulation MURELLE 20 BFR CE IONO with electronic ignition and modulation central heating only forced draught sealed room MURELLE 20 BF CE with electronic modul...

Page 6: ...values must be kept to in the D H W production The gas consumptions refer to the calorific value at standard conditions at 15 C 1013 mbar Power Smokes Smokes D H W D H W flow rate Minimum D H W pressu...

Page 7: ...eed Otherwise the pilot flame could go out owing to lack of air For the MURELLE 20 TX CE IONO 20 25 CE IONO 20 25 BF CE IONO boilers just turn on the switch 1 and choose the position on the Summer Win...

Page 8: ...ater system whether the mixing system is of the mechani cal or of the thermostat controlled type 2 the thermal output is dosed according to the tempera ture required which means a considerable saving...

Page 9: ...he pressure exceed 3 bar causing the safety valve to open call in the Authorized Technical Service Centre to carry out a check 2 5 SMOKE SAFETY DEVICE MURELLE 20 R CE IONO 20 CE 20 25 CE IONO This is...

Page 10: ......

Page 11: ......

Page 12: ...Heating Equipment Fonderie Sime S p A via Garbo 27 37045 Legnago Vr Tel 0442 631111 Fax Serv Commerciale 0442 631293 Fax Serv Tecnico 0442 631292 Cod 6151112...

Reviews: