62
1.1 INTRODUCTION
FORMAT DGT HE
are premixed gas con-
densation thermal modules that employ a
microprocessor-based technology to con-
trol and manage all the functions.
All modules are compliant with European
Directives 90/396/CE, 2004/108/CE,
2006/95/CE and 92/42/CE. For opti-
mum installation and operation, always fol-
low t he ins tr uctions pr ovided in t his
manual.
1
DESCRIPTION OF THE BOILER
214
70
70
70 70
=
=
39
50
29,5
10
79
4
200
122
290
100
60
450
169
95
ø 60/1
00
R
M
G
R3
M2
G
750
33
S3
Fig. 1
FIXTURES
R
C.H. return
G 3/4” (UNI - ISO 228/1)
M C.H. flow
G 3/4” (UNI - ISO 228/1)
G
Gas connection
G 3/4” (UNI - ISO 228/1)
R3 D.H.W. tank return
G 3/4” (UNI - ISO 228/1)
M2 D.H.W. tank output
G 3/4” (UNI - ISO 228/1)
S3 Condensation outlet
ø 25
1.2
DIMENSIONS
1.2.1
FORMAT DGT HE 12-20 T
ATTENTION:
The
“12-20 T”
version is designed for the connection of a remote
boiler, to use it as a boiler
ONLY FOR HEATING
it is necessary:
- to disconnect the D.H.W. sensor (SB)
- set the PAR 2 to 4.
All modules are designed to be used by qualified technical per-
sonnel.
Summary of Contents for FORMAT DGT HE 12