Supplied By www.heating spares.co Tel. 0161 620 6677
2
1.3
GENERAL DATA
MODE
OUTPUT
INPUT (G.C.V.)
BURNER PRESS. (Nat. gas) BURNER PRESS. (Butane/Propane)
kWBtu/h
kWBtu/h
mbar
inwg
mbar
inwg
CENTRAL HEATING RANGE
9.0
31,000
12.0
42,000
2.4
0.9
5.9/7.7
2.4/3.1
10.6
36,000
14.1
48,000
3.2
1.3
7.9/10.3
3.2/4.1
12.3
42,000
16.2
55,000
4.1
1.7
10.2/13.2
4.1/5.3
14.1
48,000
18.2
62,000
5.2
2.1
12.7/16.3
5.1/6.5
X
* (G20-G31)
15.9
54,000
20.3
69,000
6.3
2.5
15.4/19.6
6.2/7.9
X
* (G30)
17.7
60,000
22.4
76,000
7.5
3.0
18.4/23.2
7.4/9.3
19.6
67,000
24.5
84,000
8.9
3.6
21.5/26.9
8.6/10.8
21.5
73,000
26.6
90,000
10.3
4.1
24.8/30.8
10.0/12.4
23.4
80,000
28.7
98,000
11.8
4.7
28.5/36.5
11.4/14.7
DOMESTIC HOT WATER
Max.
23.4
80,000
28.7
98,000
11.8
4.7
28.5/36.5
11.4/14.7
Min.
9.0
31,000
12.0
42,000
2.4
0.9
5.9/7.7
2.4/3.1
* Factory setting
TABLE 3a - Nominal boiler ratings (5 minutes after lighting) for “FORMAT 80 C”
MODE
OUTPUT
INPUT (G.C.V.)
BURNER PRESS. (Nat. gas) BURNER PRESS. (Butane/Propane)
kWBtu/h
kWBtu/h
mbar
inwg
mbar
inwg
CENTRAL HEATING RANGE
11.4
39,000
15.0
51,000
2.6
1.0
5.5/7.1
2.2/2.9
13.5
46,000
17.5
60,000
3.5
1.4
7.4/9.4
3.0/3.8
15.6
53,000
20.0
68,000
4.5
1.8
9.7/12.1
3.9/4.8
17.7
60,000
22.5
77,000
5.6
2.3
12.2/14.9
4.9/6.0
X
* (G20-G31)
19.8
68,000
25.0
86,000
6.8
2.7
14.9/18.0
6.0/7.2
X
* (G30)
22.0
75,000
27.6
94,000
8.2
3.3
17.9/21.3
7.2/8.6
24.2
83,000
30.1
103,000
9.6
3.8
21.2/24.8
8.5/10.0
26.5
90,000
32.6
111,000
11.1
4.5
24.7/28.5
9.9/11.4
28.8
98,000
35.1
120,000
12.7
5.1
28.5/36.5
11.4/14.7
DOMESTIC HOT WATER
Max.
28.8
98,000
35.1
120,000
12.7
5.1
28.5/36.5
11.4/14.7
Min.
11.4
39,000
15.0
51,000
2.6
1.0
5.5/7.1
2.2/2.9
* Factory setting
TABLE 3b - Nominal boiler ratings (5 minutes after lighting) for “FORMAT 100 C”
MODE
OUTPUT
INPUT (G.C.V.)
BURNER PRESS. (Nat. gas) BURNER PRESS. (Butane/Propane)
kWBtu/h
kWBtu/h
mbar
inwg
mbar
inwg
CENTRAL HEATING RANGE
11.2
38,000
15.0
51,000
2.2
0.9
4.5/5.8
1.8/2.3
13.6
46,000
17.9
61,000
3.1
1.3
6.4/8.2
2.6/3.3
16.0
55,000
20.9
72,000
4.2
1.7
8.5/11.0
3.4/4.4
18.5
63,000
23.9
81,000
5.4
2.2
11.0/14.1
4.4/5.7
X
* (G20-G31)
21.0
72,000
26.8
92,000
6.8
2.7
13.7/17.6
5.5/7.1
X
* (G30)
23.6
80,000
29.8
101,000
8.3
3.3
16.7/21.4
6.7/8.6
26.2
89,000
32.7
111,000
10.0
4.0
20.0/25.6
8.0/10.3
28.9
99,000
35.7
122,000
11.8
4.7
23.5/30.0
9.4/12.0
31.6
108,000
38.6
132,000
13.7
5.5
28.2/36.2
11.3/14.5
DOMESTIC HOT WATER
Max.
31.6
108,000
38.6
132,000
13.7
5.5
28.2/36.2
11.3/14.5
Min.
11.2
38,000
15.0
51,000
2.2
0.9
4.5/5.8
1.8/2.3
* Factory setting
TABLE 3c - Nominal boiler ratings (5 minutes after lighting) for “FORMAT 110 C”