Description of parameter
Abbre
viation
Unit
Min.
Max.
Default Notes
Resistor ON interval (anti-legionella)
H0
Days
0
99
30
Anti-legionella function setpoint
H1
°C/°F
10.0
199.0
70.0
Anti-legionella function duration
H3
min
0
240
2
Enable solar thermal input (digital 1)
i0
----
0
2
2
0 = input disabled
1 = pressure input
2 = digital 1 input
Type of solar thermal input contact
(digital 1)
i1
----
0
1
0
0 = active if contact
closed
1 = active if contact
open
Compressor protection from high/low
pressure end
i2
min
0
120
0
Enable solar panel input (digital 2)
i3
----
0
1
1
0 = input disabled
1 = input enabled
Type of solar panel input contact (digital
2)
i4
----
0
1
0
0 = active if contact
closed
1 = active if contact
open
Number of digital input alarms for
appliance lock
i8
----
0
15
0
Time for digital input alarm counter reset
i9
min
1
999
240
Enable buzzer
u9
----
0
1
1
0 = buzzer disabled
1 = buzzer enabled
On time for Monday
Hd1
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
On time for Tuesday
Hd2
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
On time for Wednesday
Hd3
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
On time for Thursday
Hd4
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
On time for Friday
Hd5
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
On time for Saturday
Hd6
----
1
2
2
1 = HOn1-HOF1
2 = HOn2-HOF2
On time for Sunday
Hd7
----
1
2
2
1 = HOn1-HOF1
2 = HOn2-HOF2
Time for first automatic on
HOn1
----
00:00 23.59
--:--
--:-- = function excluded
Time for first automatic off
HOF1
----
00:00 23.59
--:--
--:-- = function excluded
Time for second automatic on
HOn2
----
00:00 23.59
--:--
--:-- = function excluded
Time for second automatic off
HOF2
----
00:00 23.59
--:--
--:-- = function excluded
Appliance address
LA
----
1
247
247