To change the day of the week:
Press and release the
button: “
dd
”
followed by two numbers indicating the day
are shown on the display;
Press and release the
button or the
button within 15 seconds.
To change the time (hours):
Press and release the
button when
changing the day of the week: “
hh
” followed
by two number indicating the time are shown
on the display (24-hour clock);
Press and release the
button or the
button within 15 seconds.
To change the time (minutes):
Press and release the
button when
changing the time: “
nn
” followed by two
numbers indicating the minutes are shown on
the display;
Press and release the
button or the
button within 15 seconds;
Press and release the
button or do not
touch the display for 15 seconds;
To exit the procedure:
Press and release the
button until the
temperature under parameter P5 is shown or
do not touch the display for 60 seconds.
Alternatively:
Press and release the
button.
To set the appliance to operate at pre-set
times, first the current day and time must
be set.
7.1.3.15
Setting the configuration parameters
To access the procedure:
Make sure that the keypad is not locked
(section 7.1.3.3) and that there are no other
advanced procedures running;
Press and hold the
button and the
button for 4 seconds: “
PA
” (password) shows
on the display;
Press and release the
button;
Press and release the
button or the
button within 15 seconds to set “
-19
” on the
display;
Press and release the
button or do not
touch the display for 15 seconds;
Press and hold the
button and the
button for 4 seconds: the first parameter “SP1”
shows on the display.
To select a parameter:
Press and release the
button or the
button.
To change a parameter:
Press and release the
button;
Press the
button or the
button to
increase or decrease the value of the
parameter (within 15 seconds);
Press and release the
button or do not
touch the display for 15 seconds.
To exit the procedure:
Press and hold the
button and the
button for 4 seconds or do not touch the
display for 60 seconds (any changes are
saved).
Turn the appliance off and back on again
to implement the changes to the
parameters.
7.1.3.16
Restore factory settings
To access the procedure:
Make sure that the keypad is not locked
(section 7.1.3.3) and that there are no other
advanced procedures running;
Press and hold the
button and the
button for 4 seconds: “
PA
” (password) shows
on the display;
Press and release the
button;
Press and release the
button or the
button within 15 seconds to set “
149
”;
Press and release the
button or do not
touch the display for 15 seconds;
Press and hold the
button and the
button for 4 seconds: “
dEF
” shows on the
display;
Press and release the
button;
Press and release the
button or the
button within 15 seconds to set “
1
”;
Press and release the
button or do not
touch the display for 15 seconds: “
dEF
” flashes
for 4 seconds on the display, then the
appliance exits the procedure;
Disconnect the power supply to the
appliance.
To exit the procedure before completion:
Press and hold the
button and the
button for 4 seconds during the procedure (i.e.
before setting “1”: the appliance is not
restored).
7.1.3.17
COUNTING THE COMPRESSOR
OPERATING HOURS
7.1.3.17.1
General information
The appliance can store up to 9999 operating
hours for the compressor. If the number of
operating hours exceeds this value, “9999” flashes.