![Sime Brava Slim BF Installation And Maintenance Manual Download Page 96](http://html.mh-extra.com/html/sime/brava-slim-bf/brava-slim-bf_installation-and-maintenance-manual_1274934096.webp)
96
EN
To enter "Parameter setting and display"refer to the indications
provided in the specific section.
Once the parameters in the table have been set, you must carry
out the "Automatic calibration procedure".
If the gas valve and/or the ignition/detection electrodeand/or the
fan
are replaced, the user must still carry out the entire phase
of "Automatic calibration procedure" described in the specific
section.
4.6
Troubleshooting
LIST OF MALFUNCTION/FAULT ALARMS
Type
Nr.
Fault
Solution
ALL
02
Low water pressure in
system
- Restore pressure
- Check for any leaks in
the system
ALL
03
High water pressure in
system
- Empty the system via
the drain valve on the
hydraulic assembly and
bring the pressure to
approximately 1.2 bar
ALL
04
Domestic hot water
sensor fault
- Check connections
- Replace the sensor
ALL
05
Delivery sensor fault
- Check connections
- Replace the sensor
ALL
06
No flame detection
- Check the integrity of
the electrode and check
that it is not grounded
- Check gas availability
and pressure
- Check the integrity of
the gas valve and the
card
ALL
07
Intervention of the
second element of the
delivery sensor
- Check the delivery
sensor connections
- Deaerate the system
- Check the bleed valve
- Replace the delivery
sensor
- Check that the pump
impeller is not blocked
ALL
08
Fault in the flame
detection circuit
- Check the integrity of
the electrode and check
that it is not grounded
- Check gas availability
and pressure
- Check the integrity of
the gas valve and the
card
ALL
09
No water circulating in
the system
- Check the rotation
of the system pump
impeller
- Check the electrical
connections
- Replace the pump
ALL
10
Auxiliary sensor fault
- Check PAR
02 "hydraulic
configuration"
- Check the electrical
connection
ALL
11
Gas valve modulator
disconnected
- Check the electrical
connection
ALL
12
Incorrect configuration
of the open /sealed
chamber
- Set the parameter
tS 0.4 (Combustion
configuration) to 0
ALL
17
Fault regarding
maximum deviation
between the 2 NTC
heating sensors
- Replace the dual
sensor
ALL
28
Maximum number of
consecutive resets
reached
- Contact the Technical
Assistance Centre
Type
Nr.
Fault
Solution
ALL
37
Fault due to low
network voltage.
- Check with tester
- Contact network provider
(ENEL)
ALL
40
Incorrect network
frequency detected
- Contact network provider
(ENEL)
ALL
41
Flame loss more
than 6 consecutive
times
- Check the detection
electrode
- Check the gas supply (open
valve)
- Check mains gas pressure
ALL
42
Button fault
- Check that buttons are
working
ALL
43
Open Therm
communication
fault
- Check the electrical
connection of the remote
control
ALL
44
Anomaly inside
electronic board
- Replace the board
ALL
62
The self-calibrating
procedure must be
carried out
- Carry out the self-calibrating
procedure (see the specific
section)
ALL
72
Incorrect
positioning of the
delivery sensor
- Check that the delivery
sensor is attached to the
delivery pipe
ALL
74
Fault in the 2nd
element of the
delivery sensor
- Replace the sensor
ALL
80
Anomaly in gas
valve control line
- Check/replace the
connection cable to the gas
valve
ALL
81
Block due to
combustion during
start-up
- Check for blockage in
chimney
- Bleed the air from the gas
circuit
ALL
83
Irregular
combustion
(temporary error)
- Check for blockage in
chimney
ALL
88
Anomaly inside
electronic board
- Replace the board
ALL
96
Block due to
clogging in smoke
outlet
- Check for blockage in
chimney
-
-
Frequent relief
valve intervention
- Check circuit pressure
- Check expansion vessel
-
-
Limited production
of domestic hot
water
- Check the diverter valve
- Check that plate heat
exchanger is clean
- Check domestic hot water
circuit valve
Summary of Contents for Brava Slim BF
Page 33: ...33 ES ...
Page 65: ...65 PT ...
Page 97: ...97 EN ...
Page 129: ...129 RU ...
Page 130: ...130 ...