41
– press and hold down the buttons
>
and
y
at the same
time for approximately 6 seconds until the water delivery
temperature appears on the display and the boiler shuts down
– close the valves which were opened previously
– disconnect the pressure gauges, carefully close the pressure
points (6) and (7), put the control panel back to the original
position and refit the front panel.
6
7
Fig. 55
Gas supply pressure
Type of gas
NATURAL GAS
UNIVERSAL LPG
Pressure (mbar/kPa)
11.3/1.13
27.5/2.75
Installation with SPLIT PIPE SYSTEM smoke outlet
Model
Heat Output
Pressure at nozzles (mbar/kPa)
NATURAL GAS
UNIVERSAL
LPG
Brava Slim 30
BFRi
Max
5.3 - 5.6
0.53 - 0.56
20.2 - 20.6
2.02 - 2.06
min
0.8 - 1.1
0.08 - 0.11
4.3 - 4.6
0.43 - 0.46
Installation with CONCENTRIC smoke outlet
Model
Heat Output
Pressure at nozzles (mbar/kPa)
NATURAL GAS
UNIVERSAL
LPG
Brava Slim 30
BFRi
Max
5.8 - 6.2
0.58 - 0.62
20.5 - 21.0
2.05 - 2.10
min
1.3 - 1.6
0.13 - 0.16
4.5 - 5.0
0.45 - 0.50
Brava Slim 30
BFRe
Max
5.8 - 6.2
0.58 - 0.62
20.5 - 21.0
2.05 - 2.10
min
1.3 - 1.6
0.13 - 0.16
4.5 - 50
0.45 - 0.50