88
EN
– press and hold down the buttons
>
and
y
at the same
time for approximately 6 seconds until the water delivery
temperature appears on the display and the boiler shuts
down
– disconnect the pressure gauges, carefully close the pres-
sure points (6) and (7), put the control panel back to the
original position and refit the front panel.
6
7
Fig. 44
Gas supply pressure
Type of gas
G20
G30
G31
Pressure
(mbar)
20
28-30
37
Installation with SPLIT PIPE SYSTEM smoke outlet
Model
Heat Out-
put
Pressure at nozzles (mbar)
G20
G30
G31
Brava Slim
25 BF
Max
12,4
28
36
min
0,8
2,3
2,9
Brava Slim
30 BF
Max
12,7
28
36
min
0,6
2,7
3,5
Installation with CONCENTRIC smoke outlet
Model
Heat Out-
put
Pressure at nozzles (mbar)
G20
G30
G31
Brava Slim
25 BF
Max
12,7
28
36
min
1,8
3,2
4
Brava Slim
30 BF
Max
13,1
28
36
min
1,5
3,9
4,9