![background image](http://html1.mh-extra.com/html/sime/20119424/20119424_installation-use-and-maintenance-instructions_1275137018.webp)
17
20119857
GB
Start-up, calibration and operation of the burner
6.10 Burner start-up cycle
Lock out is indicated by a lamp on the control box
1)(Fig. 1).
Fig. 16
D4546
~
12s
~
12s
~
5s
Lock-out due to failure to light
B
Normal
Thermostat
Motor
Flame
Lock-out lamp
Resistance
Valve
Ignition transformer
WARNING
To reset the control box, press the reset or remote
reset button.
WARNING
In the event the burner stops, in order to prevent
any damage to the installation, do not unblock the
burner more than twice in a row. If the burner locks
out for a third time, contact the customer service.
DANGER
In the event there are further lockouts or faults
with the burner, the maintenance interventions
must only be carried out by qualified, authorised
personnel, in accordance with the contents of this
manual and in compliance with the standards and
regulations of current laws.