background image

19-6422-M-01 Rev 4

22

3.3 Cleaning the Emitter Points

Remove power from the Blower. Normally, the emitter points can be 
cleaned by using a jet of compressed air to blow off any dirt that may 
have accumulated on them. A swab moistened with the IPA solution 
may be used if required. If using a swab, gently wipe the tips of the 
emitter points until all the dirt is removed.

Wire emitter points should not be bent or moved during cleaning. 
After cleaning, make sure that the emitter wires point to the center 
of the fan and are on the same horizontal plane.

The Blower uses internally-shielded emitter points that will not 
normally require replacement during the normal service life of this 
product. If you believe that the emitter points need to be replaced, 
contact Simco-Ion Technical Support ([email protected]) for 
information.

Caution:

Before performing any maintenance on emitter points, remove 
power from the ionizer. Allow a minute for the high voltage 
power supply to discharge. 

Achtung:

Ziehen Sie vor der Durchführung von Wartungsarbeiten an 
Emitter-Punkten den Netzstecker aus dem Ionisator. Lassen 
Sie die Hochspannungs-Stromversorgung eine Minute 
entladen. 

Summary of Contents for 6422e

Page 1: ...I O N I Z A T I O N S O L U T I O N S Point of Use Ionizing Blower Model 6422e 6422e AC User s Manual...

Page 2: ...es Simco Ion improves its customers business results by providing a total solution to their electrostatic discharge and electromagnetic interference challenges Simco Ion Technology Group is a division...

Page 3: ...ments 5 2 Setup Operation 7 2 1 Box Contents 8 2 2 Blower Placement 9 2 3 Power Connections 12 2 4 FMS Connection 15 2 5 Turning on the Blower 17 2 6 Alarms 18 3 Maintenance 19 3 1 Maintenance Require...

Page 4: ...19 6422 M 01 Rev 4 1 1 Description 1 1 Point of Use Ionizing Blower 1 2 IsoStat Technology 1 3 Performance 1 4 Power Requirements...

Page 5: ...state DC ion emission provides fast discharge with low airflow allowing less disturbance of delicate product The Model 6422e has a red alarm indicator LED on the front of the chassis The eight pin ter...

Page 6: ...o eliminate field induced charging Steady state DC ion emission provides fast discharge with low airflow for less disturbance of delicate product Ionizers incorporating IsoStat technology never need c...

Page 7: ...f the Blower Ionization balance is better than 20V at 1 ft 30 48 cm Table 1 Performance Testing was performed with a charge plate monitor in accordance with ionization standard ANSI ESD STM3 1 2006 of...

Page 8: ...50 Hz systems Both 14 1320 01 and 14 1330 transformers provide the Blower with appropriate 24 VAC AC DC universal power supply p n 14 1322 for use with 120 240 VAC 50 60 Hz provides the Blower with 2...

Page 9: ...19 6422 M 01 Rev 4 6...

Page 10: ...19 6422 M 01 Rev 4 7 2 Setup Operation 2 1 Box Contents 2 2 Blower Placement 2 3 Power Connections 2 4 FMS Connection 2 5 Turning on the Blower 2 6 Alarms...

Page 11: ...08 see item 2 below Certificate of Compliance This manual Power transformer depending on order 120 VAC transformer 14 1320 01 230 VAC transformer 14 1330 AC DC universal power supply 14 1322 If you or...

Page 12: ...ance on page 4 for approximate decay times versus distance Keep grounded objects away from the ionized airstream to avoid the possibility of increased offset voltages Figure 4 Model 6422e with U brack...

Page 13: ...the bracket The mounting holes are spaced 1 ft 25 4 mm apart on the centerline of the bracket Figure 5 U bracket Holes for Mounting The tilt angle of the Blower can be adjusted using the T knobs on t...

Page 14: ...longer than 12mm to attach brackets to the threaded inserts in the sides of the Blower Achtung Verwenden Sie zum Anschrauben von Halterungen an den seitlich am Gebl se Blower befindlichen Gewindeeins...

Page 15: ...he transformer or power supply into the Power In receptacle on the back of the Blower See the 1 3 Performance and 1 4 Power Requirements sections for additional information AC DC Adapter Connection Th...

Page 16: ...signed to accept wiring between 22 AWG and 16 AWG When wiring the Blower directly to a 24 VDC source observe the maximum voltage and power requirements for the unit 24 VDC 10 400 mA DC maximum and pol...

Page 17: ...ult of improper wiring connections or failure to heed maximum voltage limits will not be covered by the warranty Achtung Sch den am Produkt infolge unsachgem er Verdrahtung oder wegen unterlassener Be...

Page 18: ...ng 24 VDC power into the Blower the included terminal block Simco Ion p n 18 2308 connects the Blower to the FMS using pins 1 5 Figure 10 FMS and 24 VDC Table 3 Descriptions of all 8 Terminal Block Pi...

Page 19: ...Table 4 FMS Output States Pins Normal State Alarm State No Power 1 2 relay Contact open Contact closed Contact closed 2 3 relay Contact closed Contact open Contact open 4 5 Current Loop 4 mA OK 20 mA...

Page 20: ...19 6422 M 01 Rev 4 17 2 5 Turning on the Blower The Model 6422e Blower is on as soon as power is applied to the unit...

Page 21: ...s alarm is not a maintenance alert In most cases factory service will be required Before contacting Simco Ion for service make sure that the Blower is receiving proper input voltage per specifications...

Page 22: ...19 6422 M 01 Rev 4 19 3 Maintenance 3 1 Maintenance Requirements 3 2 Cleaning the Chassis 3 3 Cleaning the Emitter Points 3 4 Auto Clean System...

Page 23: ...and emitter points is the only routine maintenance required No readjustment of the ionizer is required after cleaning The Blower can be easily removed from the U bracket by unscrewing the side knobs...

Page 24: ...19 6422 M 01 Rev 4 21 3 2 Cleaning the Chassis Moisten a cloth with the IPA solution Wipe off any dirt that may have accumulated on the unit...

Page 25: ...wires point to the center of the fan and are on the same horizontal plane The Blower uses internally shielded emitter points that will not normally require replacement during the normal service life o...

Page 26: ...the emitter points when the blower is turned off and on During full operation of the fan the brush retracts to prevent emitter point wear Figure 11 Auto Clean System Remove any contamination sensitiv...

Page 27: ...ld up of debris Ion recommends activating the Auto Clean System at least once a week Cleaning schedules will vary depending on environmental conditions The automatic Emitter Point Cleaner can not be t...

Page 28: ...24 hour accumulation LED Indicators Green POWER red ALARM Connectors 24 VAC VDC power input 8 pin terminal block with 24 VDC input from process equipment 4 20 mA current loop FMS output relay interfa...

Page 29: ...Hz Output Voltge 24 VAC 750 mA 5 Short Circuit Protection The power supply is provided with protection against short circuit by means of a primary thermal fuse Dimensions 2 8H x 2 5W x 1 9D in 72H x 6...

Page 30: ...valuating repairing or replacing any unit returned to Simco Ion that has not been subjected to misuse neglect lack of routine maintenance repair alteration or accident In no event shall Simco Ion be l...

Page 31: ...19 6422 M 01 Rev 4 28...

Page 32: ...19 6422 M 01 Rev 4 29 Notes...

Page 33: ...19 6422 M 01 Rev 4 30 Notes...

Page 34: ...Ste 100 Alameda CA USA 94502 Tel 510 217 0600 Fax 510 217 0484 Toll free 800 367 2452 Sales services 510 217 0460 Tech support 510 217 0470 ioninfo simco ion com salesservices simco ion com techsuppor...

Reviews: