3
Output
MINIMUM
LOAD
NORMAL
LOAD
MAXIMUM
LOAD
PEAK
LOAD
LOAD
REG.
LINE
REG.
Ripple &
Noise
+3.3V
0A
10A
20A
-
±5%
±1%
50mV P-P
+5V
0A
10A
20A
-
±5%
±1%
50mV P-P
+12V
0.1A
12.25A
25A
-
±3%
±1%
120mV P-P
-12V
0A
0.15A
0.3A
-
±10%
±1%
120mV P-P
+5Vsb
0A
1.25A
2.5A
-
±5%
±1%
50mV P-P
Output
MINIMUM
LOAD
NORMAL
LOAD
MAXIMUM
LOAD
PEAK
LOAD
LOAD
REG.
LINE
REG.
Ripple &
Noise
+3.3V
0A
10A
20A
-
±5%
±1%
50mV P-P
+5V
0A
10A
20A
-
±5%
±1%
50mV P-P
+12V
0.1A
18.75A
37.5A
-
±3%
±1%
120mV P-P
-12V
0A
0.15A
0.3A
-
±10%
±1%
120mV P-P
+5Vsb
0A
1.25A
2.5A
-
±5%
±1%
50mV P-P
450W(loading shown in Amps)
Load
+3.3V
+5V
+12V
-12V
+5Vsb
Light
2.22
2.22
5.76
0.05
0.38
Typical
5.55
5.55
14.4
0.12
0.96
Full
11.1
11.1
28.79
0.23
1.92
4. OUTPUT ELECTRICAL REQUIREMENTS
3.1 Standby Power Consumption (+5Vsb):
4.1. OUTPUT VOLTAGE AND CURRENT RATING
SX300-B
SX450-B
(1) +3.3V & +5V total output not exceed 120W.
(2) Maximum combined current for the +12V outputs shall be 25A.
(1) +3.3V & +5V total output not exceed 120W.
(2) Maximum combined current for the +12V outputs shall be 37.5A.
Voltages and ripple are measured at the load side of mating connectors with a 0.1uF monolithic ceramic capacitor
paralleled by a 10uF electrolytic capacitor across the measuring terminals.
Efficiency > 45% @ 5Vsb/45mA &230Vac input (2013 Lot 6)
Efficiency > 75% @ 5Vsb/550mA &230Vac input Efficiency > 75% @ 5Vsb/1A &230Vac input
Efficiency > 75% @ 5Vsb/1.5A &230Vac input
Efficiency > 75% @ 5Vsb/2.5A &230Vac input
Summary of Contents for SFX Series