2.2. INRUSH CURRENT
2.4. AC-DC power supplies shall not perform at less than:
Table1. Loading Table for Efficiency Measurements
2.3. INPUT LINE CURRENT & POWER FACTOR (P.F.)
Maximum inrush current from power-on (with power on at any point on the AC sine) and including, but not limited to,
three line cycles, shall be limited to a level below the surge rating of the input line cord, AC switch if present, bridge
rectifier, fuse, and EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not damage the
power supply or cause the input fuse to blow.
(AC input=230V)
1. Power factor 0.8 at 20% of rated output.
2. Power factor 0.9 at 50% of rated output.
3. Power factor 0.95 at 100% of rated output.
SX300-B
SX450-B
(At Full load)
AC input
Input line current
P.F.@ Full Load
115V
< 4.5Amps – rms
> 0.95
230V
< 2Amps – rms
> 0.95
AC input
Input line current
P.F.@ Full Load
115V
< 5.5Amps – rms
> 0.95
230V
<3.0Amps – rms
> 0.95
300W(loading shown in Amps)
Load
+3.3V
+5V
+12V
-12V
+5Vsb
Light
1.99
1.99
3.44
0.04
0.34
Typical
4.97
4.97
8.6
0.1
0.86
Full
9.95
9.95
17.2
0.21
1.72
3. EFFICIENCY
Under the load conditions defined in table 1. And table 2.
The loading condition for testing efficiency shown in Table 1 represents a fully loaded system. A ~ 50% (typical)
loaded system and a ~ 20% (light) loaded system.