SLE 280 A2
■
46
│
GB
│
MT
Protection against overheating
The appliance has an overheating guard.
■
The overheating guard switches the appliance off automatically if there is a risk
of overheating.
■
For approx. 3 minutes thereafter, the appliance cannot be re-started.
■
After approx 3 minutes, the appliance re-starts automatically.
■
Check whether external factors may have triggered the overheating guard.
(e.g. temperatures above 35 °C or a closed valve
obstructing the air outlet).
Storage
♦
Remove the mains plug from the mains power socket.
♦
Coil the power cord
12
around the cable spool
11
and secure the mains
plug to the power cord
12
using the securing brace
15
provided with
the cable.
♦
Empty the water tank
5
if not using the appliance for a prolonged period.
♦
Always store the appliance in an upright position and in a dry and dust-free
environment.
Troubleshooting
This section contains important information on fault identification and rectification.
Causes of malfunction and fault rectification
The following Table will help to identify and rectify minor faults:
Fault
Possible cause
Rectification
The appliance
will not switch
on.
The mains plug is not plugged in.
Insert the mains plug into the mains
power socket.
The mains power socket is not
supplying power.
Check the house's mains fuse.
Safety stop due to the water
tank
5
being missing or having
been inserted incorrectly.
Insert the water tank
5
correctly.
The water tank
5
is full.
Empty the water tank
5
and re-insert
it.
The appliance
stops occasion-
ally (the fan
switches off).
Room temperature is below 15°C.
The defrosting function is activated. This
is a normal feature of the appliance.
The humidity in the room is below
55%.
This is a normal feature of the appli-
ance.