- 36 -
LNB type
Select the connected LNB type (standard setting is "Universal 1").
Press the arrow keys left (10) or right (11) to change the setting and to
select from "Universal 1", "Universal 2" or "Standard".
or
Press the “OK” key (14). A selection window appears.
Select the desired setting by using the arrow keys up (12) or down (13).
Confirm your selection by pressing the “OK” key (14).
Caution!
The "Standard" setting is recommended only for expert users, as the
LNB oscillator can be entered manually here (see the next point).
LNB local-freq
This setting cannot be changed in case of the settings "Universal 1" and
"Universal 2" of the LNB type.
If the "Standard" (LNB type) setting is selected, the oscillator frequency can
be entered manually.
Press the arrow keys left (10) or right (11) to change the displayed oscillator
frequency.
or
Press the “OK” key (14). The displayed oscillator frequency is deleted.
Enter the desired oscillator frequency by using the numerical pad (3).
Confirm your selection by pressing the “OK” key (14).
LNB power
Select whether LNB power supply should be switched on or off.
Press the arrow keys left (10) or right (11) to change the setting.
or
Press the “OK” key (14). A selection window appears.
Select the desired setting by using the arrow keys up (12) or down (13).
Confirm your selection by pressing the “OK” key (14).