background image

 

 

Safety Information

 

 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

DEC 101213P 

The  locations  of  the  safety  decals  fitted  to  air  assist  sprayers  are  shown  in  the 
diagrams below. The wording of the decals is shown on the following page.  
It is important that all operators read and follow the information on all safety decals 
before operating the sprayer. Failure to comply with these warnings could result in 
serious injury or death.  
Safety decals should be kept clean and legible at all times. If any decals are missing 
or  unreadable  they  should  be  replaced  by  ordering  new  decals  from  your  Silvan 
dealer using the part numbers shown.  

 

SUPAFLO 2000 AIRBLAST SPRAYER 

DECAL LOCATIONS 

 

Part No. DEC

 

68

 

Same location both 
sides 

Part No. DEC 05 

Gearbox Operation 

Part No. DEC 63 
Drain Valve 

 

Drain Valve 
Operation 

DEC 101213P 

Part No. 399 14 1000 

Fitted to PTO safety 
cover 

PTO not shown 

Part No. DEC 68 

Same location both 
sides 

STILETTO 2000 AIRBLAST SPRAYER 

DECAL LOCATIONS   

 

Part No. DEC 05 

Gearbox Operation

 

Part No. DEC 63 

Drain Valve

 

Operation 

Part No. 399 14 1000 

Fitted to PTO safety 
cover 

PTO not shown 

Summary of Contents for Stiletto 2000L

Page 1: ...Operator s Manual MANAB08 REV F 12 11 19 Air Assist Sprayer 2000L Supaflo 2000L Stiletto...

Page 2: ...tails of your sprayer here for future reference when discussing service with your Silvan dealer ordering parts or making a warranty claim SERIAL NUMBER _____________________________ MODEL ____________...

Page 3: ...ranty period begins on the date the product is delivered to the first retail purchaser for a period of 12 months This Warranty Covers Only conditions resulting directly from defects in workmanship or...

Page 4: ...hr Controls Cab mounted control box with master on off switch left right section controls and pressure regulating switch Manual pressure regulator on valve bank 100mm dia 60 Bar pressure gauge on val...

Page 5: ...working loads and relevant tractor safety instructions Exercise extreme care when operating in hilly or uneven terrain to ensure proper stability Adjust the sprayer wheel track for maximum stability...

Page 6: ...legible at all times If any decals are missing or unreadable they should be replaced by ordering new decals from your Silvan dealer using the part numbers shown SUPAFLO 2000 AIRBLAST SPRAYER DECAL LO...

Page 7: ...14 1000 Part Number DEC 68 The wording of the safety decals shown on the previous pages is given below Before operating the sprayer read all safety warning decals Failure to comply with these warnings...

Page 8: ...rns and do not exceed the allowable limit The telescoping tubes must overlap by at least 1 3 their length but not less than 150mm in all possible operating positions and there must be at least 25mm te...

Page 9: ...en key to loosen the two grub screws on the underside of the cowl that lock onto the slide bars Loosen the nuts on the top threaded rod and move the cowl to the desired position The minimum gap is 100...

Page 10: ...ngages the blade teeth at the desired pitch setting Then securely tighten the hub clamp screw to approx 20 N M of torque 15 ft lb The balance washer bolts can then be tightened by just bringing the he...

Page 11: ...0 Fan Blade Clamping Block Fan Hub Balance Screws and Washers Locating Tab Hub Clamp screw Locating Tab Hub Clamp screw 350 Pitch Reference Mark Installation Locating Teeth Locating Tab Hub Clamp Scre...

Page 12: ...drive with the tractor engine running or the PTO engaged Moving the gearbox lever to the high position produces maximum airflow The low position produces less airflow and can be used to protect the c...

Page 13: ...or the remaining sections The sprayer is then adjusted correctly Adding Chemicals Chemicals can be added to the tank through the top opening or on Supaflo models more safely and conveniently by use of...

Page 14: ...hemical manufacturer s instructions determine the quantity of chemical that needs to be added to the tank to achieve the correct strength of solution Add the required chemical through the filter baske...

Page 15: ...t higher outputs swirl plates with a central hole are needed to fill the centre of the conical spray pattern and when fitted they should be one size smaller than the ceramic jet Ceramic jets and swirl...

Page 16: ...xceed the rated capacity of the pump If it does reduce the travel speed or the application rate STEP 3 Nozzle Selection For chemical applications the jet and swirl plate combination for each individua...

Page 17: ...nal line for the Application Rate that you have chosen then draw a vertical line up to the Total Output axis to show the total litres min you will need to use The dotted arrows on the chart show an ex...

Page 18: ...1 2 1 3 1 4 1 6 1 9 1 0 CC 1 3 1 5 1 7 1 9 2 1 2 4 2 7 1 2 CC 1 7 2 0 2 3 2 6 2 8 3 2 3 5 1 5 CC 2 3 2 7 3 1 3 3 3 6 4 0 4 3 1 8 CC 2 7 3 2 3 6 4 1 4 5 5 0 5 5 2 0 CC 3 4 3 8 4 3 4 7 5 1 5 7 6 3 2 2...

Page 19: ...e to use HCC02 Orange in positions 3 7 at 11 bar pressure 2 Orchard Fruits Low Volume Spraying Application rate 1000 l ha Travel speed 5 km hr Row width 6 1 m Spraying pressure 20 Bar 1000 x 5 x 6 1 5...

Page 20: ...ha Nozzle Position from top down 1 2 3 4 5 6 7 8 Jet Swirl Plate Size 2 0 1 8 2 0 1 8 2 2 2 0 2 2 2 0 2 2 2 0 2 0 1 8 2 0 1 8 1 8 1 5 This arrangement will produce a spray pattern with a fairly unifor...

Page 21: ...3 4 5 6 7 8 Pressure Setting __________ Bar Measured Output _________ litres min from test run Output l min Application Rate x Speed x Row Width 600 x x 600 litres min Date of Test _______________ App...

Page 22: ...HCC Hollow Cone ceramic jet and the other side is fitted with a standard jet Flotation Tyres Optional flotation tyres are 400 60 x 15 5 fitted to fixed axle in lieu of the standard wheels and tyres S...

Page 23: ...of the oil level viewer Gearbox Check the oil level every 50 hours and if required top up with SAE 85W 140 gear oil The level should be halfway up the viewer on the side of the gearbox Filters Clean a...

Page 24: ...in fluid flow and should be set in accordance with the spraying pressure being used as shown in the chart below Spraying Bar pressure psi 2 5 29 73 5 10 73 145 10 20 145 290 20 50 290 725 Surge air Ba...

Page 25: ...left open Supaflo models Pressure filter flushing valve left open Fan noisy and or vibrating Gearbox bearings worn Fan damaged or out of balance Tractor PTO incorrectly installed Hitch point and PTO g...

Page 26: ...25 Notes...

Page 27: ...26...

Page 28: ...27 SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 68 Atlantic Drive Keysborough 3173 Australia Telephone 1300 745 826 Facsimilie 1800 745 826 www silvan com au...

Reviews: