background image

 

11 

 

 

Operation 

Starting the Sprayer

 

Before  starting  the  sprayer  for  the  first  time 
grease  all  lubrication  points  including  the  PTO 
shafts. Check that the oil  level  in the diaphragm 
pump  is  level  with  the  mark  in  the  viewer  and  if 
necessary  top  up  with  SAE  20W-50  multigrade 
engine  oil.    Ensure  that  the  gearbox  oil  level  is 
correct.  Refer Maintenance section for details. 

 
First  conduct  a  trial  using  clean  water  only  (no 
chemicals)  to  become  familiar  with  the  controls 
and  to  check  that  all  systems  are  functioning 
correctly without leakage.  

  
Before  filling  the  tank  check  that  the  drain  valve 
located  in  front  of  LH  ste

p  is  in  the  “pump”’ 

position,  ie.  red  handle  facing  forward.  Then  fill 
the tank through the opening after checking that 
the  basket  strainer  is  in  place  and  clean.  Close 
and rotate the lid to secure it after filling. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
On  Supaflo  models  ensure  the  shut  off  valve  in 
the  suction  filter  is  open.  It  is  open  when  the 
yellow cap is turned counter clockwise and closed 
when  it  is  pushed  in  and  turned  clockwise.  It 
automatically closes when the cap is screwed off 
which allows the filter cover to be unscrewed and  
 

 
 
 

the element to be removed for cleaning while       
there is fluid in the tank. 

 

 
 
 
 
 
 
 
 
 
 
 

 
 

 

Check that the fan gearbox is engaged and the 
required speed is selected. Never engage the 
fan drive with the tractor engine running or the 
PTO  engaged.  Moving  the  gearbox  lever  to 
the  high  position  produces  maximum  airflow. 
The low position produces less airflow and can 
be  used  to  protect  the  crop  canopy  from 
damage.  The  neutral  position  enables  the 
pump to be operated without the fan for hand 
spraying or similar operations. 
 
The  fan  incorporates  a  centrifugal  clutch    
which protects the gearbox and driveline if the 
PTO  is  engaged  rapidly.  The  sprayer  should 
always be operated at 540 PTO rpm to ensure 
correct operation of the centrifugal clutch and 
to prevent its premature wear.  

   

Flip  the  required  number  of  spray  nozzles  to 
the  open  position.  Refer  to  the  Calibration 
section  for  information  on  nozzles  and  jet 
selection. 

 

 
 
The fan incorporates a centrifugal clutch which 
protects the gearbox and driveline if the PTO 
is engaged rapidly. The sprayer should always 
be operated at 540 PTO rpm to ensure correct 
operation  of  the  centrifugal  clutch  and  to 
prevent its premature wear.  

   

Flip  the  required  number  of  spray  nozzles  to 
the  open  position.  Refer  to  the  Calibration 
section  for  information  on  nozzles  and  jet 
selection. 
Before  engaging  the  PTO,  and  with  electric 
valve controls, switch the Master valve to the 
“Off”  position.  This  places  the  pump  into  by-
pass mode and closes the outlet valves to the 
spray nozzles on either side of the sprayer. 

DRAIN VALVE 

Red Valve Handle 

SUCTION FILTER - SUPAFLO MODELS

 

Shut Off Valve 

SUCTION FILTER STILETTO MODEL 

GEARBOX SELECTION LEVER 

Summary of Contents for Stiletto 2000L

Page 1: ...Operator s Manual MANAB08 REV F 12 11 19 Air Assist Sprayer 2000L Supaflo 2000L Stiletto...

Page 2: ...tails of your sprayer here for future reference when discussing service with your Silvan dealer ordering parts or making a warranty claim SERIAL NUMBER _____________________________ MODEL ____________...

Page 3: ...ranty period begins on the date the product is delivered to the first retail purchaser for a period of 12 months This Warranty Covers Only conditions resulting directly from defects in workmanship or...

Page 4: ...hr Controls Cab mounted control box with master on off switch left right section controls and pressure regulating switch Manual pressure regulator on valve bank 100mm dia 60 Bar pressure gauge on val...

Page 5: ...working loads and relevant tractor safety instructions Exercise extreme care when operating in hilly or uneven terrain to ensure proper stability Adjust the sprayer wheel track for maximum stability...

Page 6: ...legible at all times If any decals are missing or unreadable they should be replaced by ordering new decals from your Silvan dealer using the part numbers shown SUPAFLO 2000 AIRBLAST SPRAYER DECAL LO...

Page 7: ...14 1000 Part Number DEC 68 The wording of the safety decals shown on the previous pages is given below Before operating the sprayer read all safety warning decals Failure to comply with these warnings...

Page 8: ...rns and do not exceed the allowable limit The telescoping tubes must overlap by at least 1 3 their length but not less than 150mm in all possible operating positions and there must be at least 25mm te...

Page 9: ...en key to loosen the two grub screws on the underside of the cowl that lock onto the slide bars Loosen the nuts on the top threaded rod and move the cowl to the desired position The minimum gap is 100...

Page 10: ...ngages the blade teeth at the desired pitch setting Then securely tighten the hub clamp screw to approx 20 N M of torque 15 ft lb The balance washer bolts can then be tightened by just bringing the he...

Page 11: ...0 Fan Blade Clamping Block Fan Hub Balance Screws and Washers Locating Tab Hub Clamp screw Locating Tab Hub Clamp screw 350 Pitch Reference Mark Installation Locating Teeth Locating Tab Hub Clamp Scre...

Page 12: ...drive with the tractor engine running or the PTO engaged Moving the gearbox lever to the high position produces maximum airflow The low position produces less airflow and can be used to protect the c...

Page 13: ...or the remaining sections The sprayer is then adjusted correctly Adding Chemicals Chemicals can be added to the tank through the top opening or on Supaflo models more safely and conveniently by use of...

Page 14: ...hemical manufacturer s instructions determine the quantity of chemical that needs to be added to the tank to achieve the correct strength of solution Add the required chemical through the filter baske...

Page 15: ...t higher outputs swirl plates with a central hole are needed to fill the centre of the conical spray pattern and when fitted they should be one size smaller than the ceramic jet Ceramic jets and swirl...

Page 16: ...xceed the rated capacity of the pump If it does reduce the travel speed or the application rate STEP 3 Nozzle Selection For chemical applications the jet and swirl plate combination for each individua...

Page 17: ...nal line for the Application Rate that you have chosen then draw a vertical line up to the Total Output axis to show the total litres min you will need to use The dotted arrows on the chart show an ex...

Page 18: ...1 2 1 3 1 4 1 6 1 9 1 0 CC 1 3 1 5 1 7 1 9 2 1 2 4 2 7 1 2 CC 1 7 2 0 2 3 2 6 2 8 3 2 3 5 1 5 CC 2 3 2 7 3 1 3 3 3 6 4 0 4 3 1 8 CC 2 7 3 2 3 6 4 1 4 5 5 0 5 5 2 0 CC 3 4 3 8 4 3 4 7 5 1 5 7 6 3 2 2...

Page 19: ...e to use HCC02 Orange in positions 3 7 at 11 bar pressure 2 Orchard Fruits Low Volume Spraying Application rate 1000 l ha Travel speed 5 km hr Row width 6 1 m Spraying pressure 20 Bar 1000 x 5 x 6 1 5...

Page 20: ...ha Nozzle Position from top down 1 2 3 4 5 6 7 8 Jet Swirl Plate Size 2 0 1 8 2 0 1 8 2 2 2 0 2 2 2 0 2 2 2 0 2 0 1 8 2 0 1 8 1 8 1 5 This arrangement will produce a spray pattern with a fairly unifor...

Page 21: ...3 4 5 6 7 8 Pressure Setting __________ Bar Measured Output _________ litres min from test run Output l min Application Rate x Speed x Row Width 600 x x 600 litres min Date of Test _______________ App...

Page 22: ...HCC Hollow Cone ceramic jet and the other side is fitted with a standard jet Flotation Tyres Optional flotation tyres are 400 60 x 15 5 fitted to fixed axle in lieu of the standard wheels and tyres S...

Page 23: ...of the oil level viewer Gearbox Check the oil level every 50 hours and if required top up with SAE 85W 140 gear oil The level should be halfway up the viewer on the side of the gearbox Filters Clean a...

Page 24: ...in fluid flow and should be set in accordance with the spraying pressure being used as shown in the chart below Spraying Bar pressure psi 2 5 29 73 5 10 73 145 10 20 145 290 20 50 290 725 Surge air Ba...

Page 25: ...left open Supaflo models Pressure filter flushing valve left open Fan noisy and or vibrating Gearbox bearings worn Fan damaged or out of balance Tractor PTO incorrectly installed Hitch point and PTO g...

Page 26: ...25 Notes...

Page 27: ...26...

Page 28: ...27 SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 68 Atlantic Drive Keysborough 3173 Australia Telephone 1300 745 826 Facsimilie 1800 745 826 www silvan com au...