background image

TV

TV

Water Heater

IntelliHub

Tier 1

Tier 2

Tier 3

6.  Hubcentric topology.

Your Silux Control

®

 automation system uses a technology known as 

Hubcentric topology. This means that all your devices communicate with 

each other. In larger areas, it is possible that a device might be too far 

from the IntellihHub

®

 to communicate reliably. Your IntelliHub

®

 will then 

use other devices which are more in range to create a more reliable 

connection to the out of range device. The distance at which your 

IntelliHub

®

 can communicate with your Silux Control

®

 devices varies 

according to the environment. The IntelliHub

®

 has been developed to 

achieve a distance of 20m, however, thick walls, large electrical 

appliances and long distances are 3 factors that can limit communication 

with Silux Control

®

 devices. Use the “diagnostics” section of your Silux 

Control

®

 app to diagnose any issues you might be experiencing with 

communication on your Silux Control

®

 Network.

7. What is a Trigger:

An ‘trigger’ is a device, used to control a Silux Control

®

 device. Think 

of it as a remote control. This device will only be on for a brief period 

of time while sending the command to your Silux Control

®

 device and 

will go back into sleep mode if the command was successful. Since 

this device will be in sleep mode, most of the time, it doesn’t form part 

of the intercommunication system. Please see the diagram above for 

the intercommunication system.

*Please Note: 

The Seeker

®

 and Touch Lamina

®

 are examples of end 

points.

8. Factory Reset:

This function will remove all paired devices and restore the settings to 

the original state. Press and hold the Teach button on the Thermo 

Stabilizer

©

 

for 5 consecutive seconds. On the 5th second, the light will 

flash 3 times. Your device will now be restored to its default state. 

Summary of Contents for SC-TS01

Page 1: ...OPERATION MANUAL SC TS01 Thermo Stabilzer ...

Page 2: ...th your smart device IV How to pair with Touch Lamina 6 Hubcentric Topology 7 What is a Trigger 8 Factory Reset 9 Safety precautions 10 Versions and Changes 11 More Silux Control automation products Appendix II 1 Troubleshooting 2 Warranty I What this warranty covers II What period does this warranty cover III What Silux will do to correct any problems IV What is not covered by this warranty 3 Sup...

Page 3: ... from the convenience of your living room or anywhere across the world using any smart device running Android or iOS At Silux Control we tried to keep our products as affordable as possible without compromising quality Our devices are specially designed to make it as easy as possible to install with easy usability and a wide range of applications With encrypted data control you are also protected ...

Page 4: ... other devices with a high wattage rating 4 Electrical Specifications Power supply Operating Voltages 110V AC 230V AC Power supply Frequency Range 50Hz 60Hz Maximum Switching Power Output A 4000W Output B 4000W Wire Thickness 2 5mm 3mm Operating Temperatures 5 C 60 C 5 Instructions A B STATUS Device Device Mains 2 3 OFF 1 Screw holes Thermo Stabilizer Output A Status Output B Red light Status Powe...

Page 5: ...eadings and keep the water at the selected temperature 5 Tighten all the glands and screw the plastic cover back on again You can mount the Thermo Stabilizer to a desired location using the mounting holes on the side of the Thermo Stabilizer with the supplied plugs and screws 6 Turn the main switch to this device on The RED light on the front of the device will switch on This means the Thermo Stab...

Page 6: ...ng directly to the Thermo Stabilizer the button only controls Output A 1 A red light will indicate that the the Thermo Stabilizer has power Press the Teach button on the Thermo Stabilizer The green light on the Thermo Stabilizer will start flashing 2 Ensure the Touch Lamina has power Press the Teach button on the Touch Lamina The green light on the Touch Lamina will start flashing 3 Tap the button...

Page 7: ...ices Use the diagnostics section of your Silux Control app to diagnose any issues you might be experiencing with communication on your Silux Control Network 7 What is a Trigger An trigger is a device used to control a Silux Control device Think of it as a remote control This device will only be on for a brief period of time while sending the command to your Silux Control device and will go back in...

Page 8: ...th a high humidity If water or any chemical is spilt on this device please shut the main switch or circuit breaker off Never handle this product when hands feet or body are wet or when standing on a wet floor When electrocuted consult a doctor Keep highly flammable liquids away from this device Do research about wire insulating colour codes for your country Please consult a qualified electrician W...

Page 9: ...lux has to offer 11 More Silux Control automation products Product Silux Control Name Hub IntelliHub Relay Module Dry contact Collector Relay Module Collector Relay Relay Module Dimmable Collector Dimmable Repeater Range Extender Silux RPT PIR Sensor Seeker Touch Plate EU SA Touch Lamina Altus Touch Plate USA Touch Lamina Artatus Plug Electrifier Smoke Gas Detector Halitus Water Heater Geyser Ther...

Page 10: ...rrants to the original purchaser of this Silux Control product that the product shall be free from defects in design assembly material or workmanship under normal use and operation Silux Control s sole and exclusive obligation under the foregoing warranty shall be to repair or replace at its option any defective product that fails during the warranty period The expense of removal and reinstallatio...

Page 11: ...ite at www siluxcontrol com for any other support products future products and updated user manuals 4 Disclaimer of Liability Please read this user manual thoroughly before using the product Follow all safety precautions when installing this product It is always recommended to use a qualified electrician Under no circumstances shall Silux Control or its associates be liable for any direct indirect...

Page 12: ...rranty is available on our website www siluxcontrol com Please take a moment to fill out your information Please return the warranty card with defective product and the sales receipt as proof of the date purchase Warranty cannot be carried out without it Product Model No Serial No Date of Purchase Name Surname E Mail Address Phone No Address Country D D M M Y E A R Cut Here ...

Reviews: