AN633
Rev. 0.7
49
9.5.5. Full Radio Driver
Function Name:
void
si446x_func_info
(void)
Description:
Sends the FUNC_INFO command to the radio, then reads the response into
Si446xCmd union.
Return Value:
None
Function Name:
void
si446x_frr_a_read
(U8 respByteCount)
Description:
Reads the Fast Response Registers starting with A register into Si446xCmd union.
Input Parameter(s):
respByteCount : Number of Fast Response Registers to be read.
Return Value:
None
Function Name:
void
si446x_frr_b_read
(U8 respByteCount)
Description:
Reads the Fast Response Registers starting with B register into Si446xCmd union.
Input Parameter(s):
respByteCount : Number of Fast Response Registers to be read.
Return Value:
None
Function Name:
void
si446x_frr_c_read
(U8 respByteCount)
Description:
Reads the Fast Response Registers starting with C register into Si446xCmd union.
Input parameter(s):
respByteCount : Number of Fast Response Registers to be read.
Return value:
None
Function Name:
void
si446x_frr_d_read
(U8 respByteCount)
Description:
Reads the Fast Response Registers starting with D register into Si446xCmd union.
Input Parameter(s):
respByteCount : Number of Fast Response Registers to be read.
Return Value:
None
Function Name:
void
si446x_get_adc_reading
(U8 ADC_EN)
Description:
Reads the ADC values from the radio into Si446xCmd union.
Input Parameter(s):
ADC_EN : ADC enable parameter.
Return Value:
None
Function Name:
void
si446x_get_packet_info
(U8 FIELD_NUMBER_MASK, U16 LEN, S16 DIF-
F_LEN )
Description:
Receives information from the radio of the current packet. Optionally can be used to
modify the Packet Handler properties during packet reception.
Input Parameter(s):
FIELD_NUMBER_MASK : Packet Field number mask value.
LEN : Length value.
DIFF_LEN : Difference length.
Return Value:
None
Summary of Contents for EZRADIOPRO Si4060
Page 24: ...AN633 24 Rev 0 7 Figure 20 Supply Current versus Time Diagram from Shutdown to RX State...
Page 67: ...AN633 Rev 0 7 67 Figure 48 Variable Length Packet Reception Flowchart...
Page 69: ...AN633 Rev 0 7 69 Figure 50 Packet Matching Reception Flowchart...
Page 73: ...AN633 Rev 0 7 73 Figure 54 Packet Reception with Automatic RX Hopping Flowchart...
Page 75: ...AN633 Rev 0 7 75 Figure 56 Packet Reception with Manual Rx Hopping...
Page 80: ...AN633 80 Rev 0 7 Figure 62 Long Packet Transmission Workflow...
Page 81: ...AN633 Rev 0 7 81 Figure 63 Long Packet RX Flowchart...