Power Supply
21
Power Supply
Specifications of the Origin200 power supply are as follows:
Warning:
When using an uninterruptable power supply (UPS) with an Origin200
server, be sure that the UPS can supply up to 140 A of inrush current. Each Origin200
module can draw up to 140 A of current briefly when you power it on, even though the
sustained current drawn is only a fraction of that. Some UPS units cannot supply that
much inrush current and will be damaged if you use them with an Origin200 server.
In addition, there is the possibility of fire or other hazard if these UPS units are unable
to supply sufficient current.
Table 1-4
Origin200 Server Power Supply Specifications (per Module)
Specification
Value
Input volts
100 to 120 VAC, and 200 to 240 VAC, autoranging
Input watts
805 watts (for a fully configured module)
Input amps
8 amps at 100 VAC
4 amps at 240 VAC
Input volt-amps
800 VA
Inrush current
140 amps maximum
Frequency
47 Hz to 63 Hz
Output volts
+5 VDC
+12 VDC
-12 VDC
+3.45 VDC
Output watts
483 watts (for a fully configured system)
Power factor
Unity power-factor corrected (0.98)
Efficiency
60%
Summary of Contents for Origin200
Page 1: ...Origin200 Owner s Guide Document Number 007 3415 003 ...
Page 4: ...Origin200 Owner s Guide Document Number 007 3415 003 TUV geprufte Sicherheit R NRTL C ...
Page 12: ......
Page 28: ......
Page 54: ......
Page 88: ......
Page 98: ......
Page 100: ......
Page 138: ......
Page 152: ......
Page 164: ...138 Chapter 6 Installing and Removing Memory Figure 6 8 Removing DIMMs ...
Page 166: ......
Page 168: ......
Page 184: ......
Page 216: ......
Page 222: ......
Page 250: ......
Page 252: ......
Page 260: ......
Page 270: ......
Page 272: ......
Page 286: ......
Page 288: ......