60
007-5536-001
A: Technical Specifications
Environmental Specifications
Table A-2 lists the environmental specifications of the system.
Table A-2
Environmental Specifications
Feature
Specification
Temperature tolerance
(operating)
+5
°
C (41
°
F) to +35
°
C (95
°
F) (up to 1500 m / 5000 ft.)
+5
°
C (41
°
F) to +30
°
C (86
°
F) (1500 m to 3000 m /5000 ft. to 10,000 ft.)
Temperature tolerance
(non-operating)
-40
°
C (-40
°
F) to +60
°
C (140
°
F)
Relative humidity
10% to 80% operating (no condensation)
8% to 95% non-operating (no condensation)
Cooling requirement
Ambient air or optional water cooling
Maximum altitude
10,000 ft. (3,049 m) operating
40,000 ft. (12,195 m) non-operating
Acoustical noise level
Less than 65 dBa maximum