REPLACING THE JAWS ON RIGHT-HAND CLAMP
Fig. 23
Make sure the motor ON switch is OFF
8.4.1
REPLACING LEFT JAW
1) Unscrew the knob (E1).
2) Loosen the 2 screws (B2) and remove the jaw.
3) Fit the new jaw up against the left-hand side and align also
from the front.
4) Tighten the 2 screws (B2) without exerting pressure.
5) Screw in the knob (E1).
6) Fully tighten the screws (B2).
Fig. 24
8.4.2
REPLACING RIGHT JAW
1) Unscrew the knob (E1).
2) Loosen the 2 screws (B3) and remove the jaw.
3) Fit the new jaw up against the right-hand side and align
also from the front.
4) Tighten the 2 screws (B3) without exerting pressure.
5) Screw in the knob (E1).
6) Fully tighten the screws (B3).