Replacing the fuses
ATTENTION: unplug the machine from the mains.
1) detach the wiring from the machine plug;
2) turn the key-cutting machine so that the fuse box is easily reached;
3) remove the fuse box placed below the power inlet (Q) (fig. 20);
4) replace the fuses (P);
5) close the fuse box and connect the power cable.
ATTENTION: the fuses must both be of the same type (rapid) and with the same amps (3,15A for the 230V
machine, 6,3A for the 110V version).