DELTA 2000 FO
Operating manual - English
14
Copyright Silca 1998
7
MAINTENANCE
ATTENTION: for repairs or replacement of parts for maintenance, the ‘CE’ mark is guaranteed only if original spare
parts provided by the manufacturer are used.
Although the DELTA 2000 FO key-cutting machine does not require special maintenance, it is advisable
to check and, if necessary, replace the parts subject to wear (cutting tool, brush, tracer point).
Replacement is simple and can be carried out by the operator.
CLEANING
: it is advisable to use a soft brush to keep the carriage and clamps free of chippings from
cutting operations.
ATTENTION: DO NOT USE COMPRESSED AIR!
ATTENTION: to keep the machine well maintained we recommend using protective oil, e.g. WD40 or similar, applied
to the burnished mechanical parts. This prevents oxidation of the parts in question (clamps, guides,
carriages, etc.).
Before starting any type of maintenance (checks or replacements), read the instructions below:
•
never carry out maintenance or servicing with the machine switched on.
•
always remove the mains plug.
•
follow all the instructions in the manual to the letter.
•
use original spare parts.
•
always check that any screws or nuts removed when replacing a piece are properly
tightened.
7.1
Cutting tool replacement
It is not necessary to remove the protective
shield in order to replace the cutting tool (G).
ATTENTION: unplug the machine from the mains.
1) place the spanner provided in position on
the motor shaft (fig.18);
2) use a suitable spanner to loosen the new
cutting tool locking nut.
ATTENTION: the thread is left-handed.
3) replace the cutting tool after cleaning its
seat;
4) install the new cutting tool and tighten the
nut.
ATTENTION: the tool rotates clockwise.
Fig. 18
7.2
Brush replacement
When the brush (J) is no longer effective it must be replaced, as follows:
ATTENTION: unplug the machine from the mains.
1) place the spanner provided in position on the motor shaft (fig.18);
2) use the wrench provided to loosen the brush locking screw (X) (fig.19);
3) replace the brush and secure with the screw;
4) remove the spanner from the motor shaft.
Fig. 19