Required accessories for heating plates:

The BT710 and BT010 room thermostats require a receiver.

PT712 - digital thermostat with room sensor (Item no. 50446)

- Enables regulation based on the room temperature

- The required temperature can be changed quickly

- 2 weekly programmes with 6 temperature changes per day

- Power reserve for more than 100 hours in the event of a 

  power cut

BT710 - radio room thermostat (Item no. 50434)

- Used to switch electrical heating systems in houses, 

  apartments and offices on and off based on the temperature

- Can control up to 9 receivers

- Simple and flexible installation - without mains 

  connection and cables

BT010 - radio room thermostat (Item no. 50435)

- Can trigger one receiver

- The range within a building is at least 35 m depending on

  the receiver

- Benefits: the set temperature can be changed quickly using the hand 

  wheel, quick selection switch for night moderation, frost protection

IPP-R01 - Empfänger für BT710 und BT010 - Unterputz 

(Item no. 50648)

- Suitable for switching infrared heaters, electric radiators, etc. 

  on and off

- The BT001 switches the connected consumers off and on based on the 

  data transferred from the transmitter

BT003 - Empfänger für BT710 und BT010 

- in einer Zwischensteckdose (Item no. 50437)

- Suitable for switching infrared heaters, electric radiators, etc. 

  on and off

- The BPT003 switches the connected consumers off and on based on the 

  data transferred from the transmitter

- Plugged directly into the socket

TS20 - Thermoschaltersteckdose (Item no. 50520)

- is a digital, temperature-dependent, switched socket for automatic 

  regulation of SIKU Infraplate pro series electrical heating systems

- up to six time intervals with three temperature levels can be set 

  for each day

NOTE:

Info according to new ERP- Standard 1188:

As of 2018, Infraplate pro Infrared non-storage type heating appliance 

must be operated only as a combination of a room thermostat with 

integrated timer and room ventilation detection device.

Summary of Contents for 50585

Page 1: ...SIKU Infraplate pro Classic SLIM INSTRUCTION MANUAL EN ID 1000000000...

Page 2: ...recautions 6 Product characteristics 7 Technical data 8 Accessories 10 Equipment configuartion 10 Installation 11 Troubleshooting 12 Maintenance repair 12 Disposal 12 Manufacturer s warranty 13 Warran...

Page 3: ...3 DELIVERY SCOPE WARNING SIGNS A infrared heating plate B screws C dowel D drilling template...

Page 4: ...IPP 240 SLIM DW Art Nr 50585 SIKU Infraplate pro IPP 400 SLIM DW Art Nr 50586 SIKU Infraplate pro IPP 550 SLIM DW Art Nr 50587 SIKU Infraplate pro IPP 800 SLIM DW Art Nr 50588 DW refers to Ceiling ins...

Page 5: ...witch for night moderation frost protection IPP R01 Empf nger f r BT710 und BT010 Unterputz Item no 50648 Suitable for switching infrared heaters electric radiators etc on and off The BT001 switches t...

Page 6: ...ant supervision or instruction regarding the use and dangers associated can be guaranteed Children aged between 3 and 8 years must neither connect the device with a power circuit nor regulate clean ma...

Page 7: ...burnings or similar accidents it must be made sure that the hot plate is disconnected from the power source and allowed to cool down completely before any cleaning works are performed A dry cloth sho...

Page 8: ...Room sizes Certificates IPP1100 SLIMWW 1205x905x15 1100 W 4 8 A 6 1 kg bis zu 16m RoHS CE T V GS IPP240 SLIMDW 605x505x15 240 W 1 0 A 2 0 kg bis zu 3m RoHS CE IPP400 SLIMDW 905x605x15 400 W 1 7 A 3 2...

Page 9: ...electronic heat charge control with room and or outdoor temperature feedback N A fan assisted heat output N A Type of heat output room temperature control select one single stage heat output and no ro...

Page 10: ...uminum alloy 4 Frame made of aluminum alloy SIKU IPP DAS ceiling suspension set Item no 50432 4 x 1 meter steel wire load capacity up to 30 kg Length adjustment and locking Weight 0 12 kg Load capacit...

Page 11: ...ces Fix drilling template D to the wall drill holes Insert dowels C Position bolts B into the bowels Fasten bolts The bolts should extrude about 0 5 cm from the wall Suspend infra red hot plate A Conn...

Page 12: ...occurrence TROUBLESHOOTING 1 The device must always be disconnected from the power source before the performance of cleaning works 2 Wipe exterior of the hot plate with damp or dry cloth 3 There must...

Page 13: ...ing a guarantee claim please contact dealer or office siku at firstly This warranty card can be sent once we receive and confirm your request as well as other relevant information Thanks very much Rem...

Page 14: ...____________ _________________________________________________________________________ Dealer Info Dealer Name _____________________________________________________________ Purchase Date _____________...

Page 15: ...15...

Page 16: ...SIKU VertriebsgmbH Bundesstra e 5 2102 Bisamberg Austria Tel 43 2262 61 521 www siku at office siku at...

Reviews: