9
Heat output
Models
Expanse of
heat rays
Nominal heat
output
Maximum
continuous heat
output
Auxiliary power
consumption at
Nominal heat output
IPP1100
SLIMWW
2,1 m
1,1 kW
1,1 kW
1,15 kW
IPP240
SLIMDW
0,7 m
0,3 kW
0,3 kW
0,312 kW
IPP400
SLIMDW
1,2 m
0,6 kW
0,6 kW
0,608 kW
IPP550
SLIMDW
1,4 m
0,7 kW
0,7 kW
0,732 kW
IPP800
SLIMDW
1,9 m
1,1 kW
1,1 kW
1,15 kW
Type of heat input, for electric storage local space heaters only (select one)
manual heat charge control, with integrated thermostat
N/A
manual heat charge control with room and/or outdoor
temperature feedback
N/A
electronic heat charge control with room and/or outdoor
temperature feedback
N/A
fan assisted heat output
N/A
Type of heat output/room temperature control (select one)
single stage heat output and no room temperature control
NO
Two or more manual stages, no room temperature control
NO
with mechanic thermostat room temperature control
NO
with electronic room temperature control
NO
electronic room temperature control plus day timer
NO
electronic room temperature control plus week timer
YES
Other control options (multiple selections possible)
room temperature control, with presence detection
NO
room temperature control, with open window detection
NO
with distance control option
NO
with adaptive start control
YES
with working time limitation
NO
with black bulb sensor
NO