4.2 Electrical installation
Destruction of parts of equipment and loss of regulation control
`
All lines for connecting the inclinometer must be shielded.
`
Never wire or disconnect electrical connections while they are live.
`
Perform wiring work in the de-energized state only.
`
Use strands with suitable ferrules.
`
Ground (GND) must be connected with the protective earth conduc-
tor (PE).
`
Wiring to the screen and ground (GND) must be secured to a good
point. Ensure that the connection of the screen and earth is made to a
large surface area with a sound connection to minimise impedance.
`
Check all lines and plug connections before switching on the device.
`
Switch on operating voltage together with the downstream electronic
unit (e. g., control unit).
Basically, all connections are protected against external interference.
Choose a place of operation that excludes inductive or capacitive interfer-
ence influences on the inclinometer. When mounting the system keep a
maximum possible distance from lines loaded with interference. If neces-
sary, provide additional installations including screening shields or met-
allized housings.
In order to avoid unintentional displacing of the inclinometer fasten the
connection cable at a distance of 10 ... 12 cm from the sensor using a
cable clamp.
Pin assignment
•
Plug pin 8 pin (M12 A-coded)
For mating connector and cable extension accessories see chapter
PIN
Designation (1 axis) Designation (2 axes)
1
+UB
+UB
2
Do Not Connect
Do Not Connect
3
Do Not Connect
Do Not Connect
4
GND
GND
5
Z axis Output U/I
X axis Output U/I
6
SET1
SET1
7
Do Not Connect
Y axis Output U/I
8
Do Not Connect
Do Not Connect
WARNING
NOTICE
viewing side =
plug-in side
3
2
8
7
6
5
4
1