Siko IK360L Translation Of The Original Installation Instructions Download Page 16

IK360L

Safety information English

IK360L · Date 

01.09.2020 · Art. 

No. 

89208 · Mod. 

status 

198/20

16

Danger that may cause minor injury, property damage or unplanned device 

reactions if you disregard the instructions given.

Important operating information that may facilitate operation or many 

cause unplanned device reactions if disregarded including possible prop-

erty damage.

Signal symbols

2.3  Target group

Installation instructions and User manual are intended for the configura-

tion, commissioning and mounting personnel of plant or machine manu-

facturers who possess special expertise in drive technology. This group of 

operators needs profound knowledge of a inclinometer's necessary con-

nections and its integration into a complete machinery.

Insufficiently qualified personnel

Insufficiently qualified personnel cause personal injury, serious damage to 

machinery or inclinometer.

 

`

Configuration, commissioning, mounting and maintenance by trained 

expert personnel only.

 

`

This personnel must be able to recognize dangers that might arise 

from mechanical, electrical or electronic equipment.

Qualified personnel are persons who

• 

are familiar with the safety guidelines of the electrical and automation 

technologies when performing configuration tasks;

• 

are authorized to commission, earth and label circuits and devices/

systems in accordance with the safety standards.

2.4  Basic safety information

Danger of explosion

 

`

Do not use the inclinometer in explosive zones.

CAUTION

NOTICE

WARNING

DANGER

Summary of Contents for IK360L

Page 1: ...198 20 IK360L Inklinometer Originalmontageanleitung Deutsch Seite 2 Inclinometer Translation of the Original Installation Instructions English page 14...

Page 2: ...sen 3 2 3 Zielgruppe 4 2 4 Grundlegende Sicherheitshinweise 5 3 Identifikation 5 4 Installation 5 4 1 Mechanische Montage 5 4 2 Elektrische Installation 6 5 Inbetriebnahme 7 5 1 Analoger Spannungsausg...

Page 3: ...Er misst den Winkel absolut zum Lot Der Inklinometer ist nur f r die Verwendung im Industriebereich vorgese hen die keinen besonderen elektrischen oder mechanischen Sicherheits anforderungen unterlieg...

Page 4: ...ntnisse innerhalb der Antriebstechnik verf gt Dieser Personenkreis ben tigt fundierte Kennt nisse ber die notwendigen Anschl sse eines Inklinometers und deren Integration in die komplette Maschinenanl...

Page 5: ...eichnung zu z B IK360L 0023 Varianten Nr Ger te Typ 4 Installation 4 1 Mechanische Montage Der IK360L ist ein vorkalibriertes Ger t das sofort in Betrieb genom men werden kann Die Montagefl che muss p...

Page 6: ...rfolgen Der Anschluss der Abschirmung an den Potentialausgleich muss gro fl chig niederimpedant erfolgen Vor dem Einschalten sind alle Leitungsanschl sse und Steckverbindun gen zu berpr fen Betriebssp...

Page 7: ...hme Nachfolgende Diagramme gelten bei Werksausf hrung unskaliert siehe Benutzerhandbuch Nach Montage und vollst ndiger Verdrahtung kann das System in Betrieb genommen werden Der Sensor wurde werkseiti...

Page 8: ...Volt pro Beispiel Uout 1 6662 V Positionswinkel 1 6662 V 0 02777 V pro 60 5 0 45 90 135 180 225 270 315 359 9 10 0 Spannung V Winkel 2 Achsen Umrechnung von Spannung Uout auf den Winkel Positionswink...

Page 9: ...den des Anschlusskabels mit ihrem Messsystem 1 Achse Pin 5 und 4 siehe Kapitel 4 2 2 Achsen f r die X Achse Pin 5 und 4 f r die Y Achse Pin 7 und 4 siehe Kapitel 4 2 Der Strom Iout kann direkt oder in...

Page 10: ...piel Iout 8 31 mA Positionswinkel 8 31 mA 4 mA 0 0444 mA pro 97 07 5 0 45 90 135 180 225 270 315 359 9 25 20 15 10 0 Strom mA Winkel 2 Achsen Umrechnung von Strom Iout auf den Winkel Positionswinkel i...

Page 11: ...nometer vor sch dlichen physikalischen Einfl ssen wie Staub Hitze und Feuchtigkeit sch tzen Anschl sse weder durch mechanische noch durch thermische Einfl sse besch digen Vor Montage ist der Inklinome...

Page 12: ...itt geschirmter Leitungen 0 5 mm Kabeldurchlass 6 8 mm Zubeh r SIKO Art Nr 83525 Buchse 8 pol Montage Abb 5 1 Dichtung an Schirmring 4 montieren 2 Teile 1 6 ber Kabelmantel schieben 3 Kabel abmanteln...

Page 13: ...0 mA 0 12 mA Last 270 R 4 20mA 2 Achsen Genauigkeit 0 5 bei 10 40 C Grenzfrequenz 100 Hz ohne Filter Systemdaten Erg nzung Aufl sung 0 01 Messbereich 360 1 Achse X und Y 80 80 2 Achsen Umgebungsbeding...

Page 14: ...rget group 16 2 4 Basic safety information 16 3 Identification 17 4 Installation 17 4 1 Mechanical mounting 17 4 2 Electrical installation 18 5 Commissioning 19 5 1 Analog voltage output 19 5 2 Analog...

Page 15: ...n absolute relation to the plumb line The inclinometer is only intended for use in industrial appli cations that are not subject to special electrical or mechanical safety requirements 1 Observe all s...

Page 16: ...knowledge of a inclinometer s necessary con nections and its integration into a complete machinery Insufficiently qualified personnel Insufficiently qualified personnel cause personal injury serious...

Page 17: ...1 Mechanical mounting The IK360L is a pre calibrated instrument that can be put into operation immediately The mounting area must be level free from dust and grease Use 3 pieces of M4 cylinder bolts...

Page 18: ...nstream electronic unit e g control unit Basically all connections are protected against external interference Choose a place of operation that excludes inductive or capacitive interfer ence influence...

Page 19: ...e downstream electronics unit must be 5 k Connect the appropriate open ends of the connection cable with your mea suring system 1 axis pins 5 and 4 see chapter 4 2 2 axes for X axis pins 5 and 4 for Y...

Page 20: ...0 10 5 0 50 60 70 80 50 60 80 Voltage V Angle X axis 70 40 30 20 10 0 10 20 30 40 10 5 0 50 60 70 80 50 60 80 Voltage V Angle Y axis 5 2 Analog current output Connect the appropriate open ends of the...

Page 21: ...Vout 1 08 V GND 2 1 3 RLoad 270 1 axis Conversion of current Iout to the angle Position angle in Iout 4 mA 0 0444 mA pro Example Iout 8 31 mA Position angle 8 31 mA 4 mA 0 0444 mA pro 97 07 5 0 45 90...

Page 22: ...Transport and storage Handle transport and store inclinometer with care Pay attention to the following points Transport and or store inclinometer in the unopened original pack aging Protect inclinome...

Page 23: ...7 Accessory connector not included in the scope of delivery 7 1 Mating connector M12 straight inclusive cable Accessory SIKO art no KV08S3 7 2 Straight mating connector M12 Advice Strand cross section...

Page 24: ...l information Operating voltage 10 30 V DC Power input 0 7 W Interface Z 0 10 V 0 0 V load 1 mA 0 10V 1 axis X and Y 0 10 V 0 5 V load 1 mA 0 10V 2 axes Z 4 20 mA 0 4 mA load 270 R 4 20mA 1 axis X and...

Page 25: ...issible EMC EN 61000 6 2 interference resistance immis sion EN 61000 6 4 emitted interference emission Protection category IP68 EN 60529 installed with suitable mating connector IP6K9K ISO 20653 insta...

Page 26: ...IK360L 26...

Page 27: ...IK360L 27...

Page 28: ...6 Buchenbach Telefon Phone 49 7661 394 0 Telefax Fax 49 7661 394 388 E Mail info siko global com Internet www siko global com Service support siko global com nderungen vorbehalten Subject to technical...

Reviews: