Specification 

Measuring ranges: 

Display range: 

-10.0 to 350.0 mbar relative (under pressure down to –350.0 mbar, p.r.t. chapter 5) 

Overload: 

max. 1000 mbar rel. (without destruction or recalibration of sensor being 

necessary) 

Resolution: 

0.1 mbar 

(

10 Pa) 

Pressure units: 

mbar, bar, kPa, MPa, mmHg, PSI mH

2

O (only for devices with ‚m‘ printed below 

display), selectable 

Accuracy: (typ.) 

±0,2%FS (hysteresis and linearity) 

±0,4%FS (temperature dependency 0-50°C) 

 

OPTION higher accuracy:  

±0.1%FS (hyst., lin.) 

 

 

 

 

 

±0.4%FS (temp. dep. 0-50°C) 

Measuring rate: 

4 meas./sec  

Nominal temperature:  25°C 

 

 

Sensor: 

Piezo-resistive relative pressure sensor integrated in device. Suitable for air and 

non-corrosive and non-ionizing gases and liquids. 

(Not suitable for water – use air buffering) 

Connection:  

2 metal pressure ports for connection to 6 x 1 mm tubes at the top of device (4mm 

inner tube Ø) 

 

Power-Off-Function:

   Device will be automatically switched off if no key is pressed/no interface 

communication takes place for the time of the power-off delay. The power-off delay 

can be set to values between 1 and 120 min.; it can be completely deactivated.  

 

Display

2 four digit LCDs (12.4mm high and 7 mm high) for measuring values, and for min/ 

max memories, hold function, etc. as well as additional functional arrows. 

 

Pushbuttons

:  

6 membrane keys 

 

Interface

Serial interface (3.5mm jack) can be connected to RS232 interface of a PC via 

electrically isolated interface adapter GRS3100 or GRS3105 (see accessories). 

 

Power supply

:  

9V battery, type: IEC 6F22  (included in scope of supply)  

as well as additional d.c.connector (diameter of internal pin 1.9 mm) for external 

10.5-12V direct voltage supply. (suitable power supply: GNG10/3000) 

Power consumption:  

Slow measuring rate: < 1.2 mA   

Low battery warning: 

!

-display and ' bAt ' 

 

Housing

:  

impact-resistant ABS, membrane keyboard, transparent panel, Front side IP65 

Dimensions:  

142 x 71 x 26 mm (L x W x D) + metal pressure ports 11mm at top of device 

Working temperature:  0...+50°C 

Allowable rel. humidity:  0...95 % r.H. (not condensing) 

Storage temperature:  -20...+70°C 

 

EMC

The MH3160-07 device corresponds to the essential protection ratings established 

in the Regulations of the Council for the Approximation of Legislation for the 

member countries regarding electromagnetic compatibility (89/336/EWG).  

Additional fault:  

<1%  

 

Summary of Contents for MH3160-07

Page 1: ...H Co KG Struthweg 7 9 34260 Kaufungen Germany 1 8 Tel 49 5605 803 0 Fax 49 5605 803 54 email info SIKA net web www SIKA net User s Manual Handheld Digital Precision Manometer MH3160 07 10 0 to 350 0 m...

Page 2: ...vice and sensors have to be handled with care don t throw hit etc Protect plugs and sockets from soiling 3 If the device is transported from a cold to a warm environment condensation may cause in a fa...

Page 3: ...ke sure that the operating voltage stated at the power supply is identical to the mains voltage Connections Connection for pressure tubes higher pressure lower pressure Interface Connection for el iso...

Page 4: ...e parameters can be changed with key 2 or key 5 Quit key 6 finishes the configuration and returns to standard measuring operation Unit Coice Of The Display Unit Choose the desired display unit the ref...

Page 5: ...e it when necessary System error Disconnect battery and power supplies wait shortly then reconnect No display or confused characters device does not react on keypress Device defective Return to manufa...

Page 6: ...nufacturer is capable to do efficient recalibration if necessary to get results of highest accuracy The Serial Interface By means of the serial interface and a suitable electrically isolated interface...

Page 7: ...6 Read min memory 200 Read min display range 7 Read max memory 201 Read max display range 12 Read ID number 202 Read display range unit 174 Clear min memory 204 Read display range decimal point 175 C...

Page 8: ...ce for the time of the power off delay The power off delay can be set to values between 1 and 120 min it can be completely deactivated Display 2 four digit LCDs 12 4mm high and 7 mm high for measuring...

Reviews: