SIKA, Dr. Siebert & Kühn GmbH & Co. KG, Struthweg 7-9, 34260 Kaufungen, Germany
3/8
Tel: +49-5605-803-0, Fax: +49-5605-803-54, email: [email protected], web: www.SIKA.net
main display:
shows measuring value.
!
: indicates weak battery or other warnings
secondary display:
min-, max- or hold value
Logg:
no function
AL:
no function
Units:
an arrow points to
the chosen measuring unit
Tara:
appears if tara-
function is activated.
SL:
no function
Operation And Maintainance Advice
•
Battery Operation
If
and ´bAt´ are shown in the secondary display the battery has been used up and needs to be
replaced. The device will, however, operate correctly for a certain amount of time. If ´bAt´ is shown in
the upper display the voltage is too low to operate the device; the battery has been completely used up.
Please note: We recommend to take out battery if device is not used for a longer period of time!
•
Mains Operation With Power Supply
Warning:
When using a power supply please note that operating voltage has to be 10.5 to 12 V DC.
Do not apply overvoltage!! Cheap 12V-power supplies often have excessive no-load voltage.
We, therefore, recommend using regulated voltage power supplies. Trouble-free operation is
guaranteed by our power supply GNG10/3000.
Prior to connecting the power supply to the mains make sure that the operating voltage stated at the
power supply is identical to the mains voltage.
Connections
Connection for pressure tubes: „+“ = higher pressure, „-“ = lower pressure
Interface: Connection for el. isolated interface adapter (p.r.t. chapter 0)
The mains adapter socket is located at the left side of the device.
Display
Basic
Operation
When switching on the device and a zero point adjustment was carried out it shows shortly „nuLL Corr“.
On-/Off-Switch
Tara:
Calling of tara function, zero point adjustment
min/max:
Showing the min- resp. max-memory in sec. display
Store/Quit:
Calling of hold function
Set/Menu:
Calling of configuration
Max Memory:
Pressing ´max´ (key 2) shows the maximum of the measured
values. Pressing it again hides it. To clear the max memory press key ´max´ for >2
seconds.
Min Memory:
Pressing ´min´ (key 5) shows the minimum of the measured values. Pressing it again
hides it. To clear the min memory press key ´min´ for >2 seconds.
Hold Function:
By pressing ´Store/Quit´ (key 6) the last measuring value will be held in the secondary
display. Pressing it again hides it.
Tare Function:
By pressing ´Tara´ (key 3) the display will be set to 0. All measurings from then on will be
displayed relatively to the set tare value. When tara function is activated, the arrow
"Tara" appears in the display. To deactivate tare function press ´Tara´ for >2 seconds.
Please Note: Activating/deactivating tara clears the max- & min-memories.
1
2
3
4
5
6
ON
OFF
max
Tara
Store
min
Set
Menu
Quit
!