The
e1
command allows to view the statistics and to configure the E1
interface.
Execution of the command without options and arguments shows current
settings of the interface:
: e1
E1A: Long-Haul FRAMED CAS Code HDB3 - ONLINE
:
3.4.1 Long/Short Haul modes
The
short
option of the
E1
command turns off the Е1 interface line
amplifier. The
long
option conversely turns it on. Respectively, the short-
haul mode range is within 400 meters (1200 feet) for 0.4 mm wire (26 AWG)
cable. The long-haul mode range is expanded up to 1200 meters (3600
feet).
: e1 long
E1A: Long-Haul UNFRAMED Code=HDB3 – ONLINE
: e1 short
E1A: Short-Haul UNFRAMED Code=HDB3 – ONLINE
:
3.4.2 Framing modes and superframe options
The G.704 framed mode is enabled by the
е1
command with the
framed
option and additional keys
crc4
and
cas
. These keys defines enable the
appropriate CRC4 and CAS superframes.
: e1 framed crc4 cas
E1A: Long-Haul FRAMED CRC4 CAS Code=HDB3 – ONLINE
:
27