WALL MOUNT
W
A
LL
POWER MODULE
J- BOX
4"x4"x2 1/8"
1900
EXTENSION
4"x4"x1 1/2"
CANOPY
-2-
ALL INSTALLATIONS REQUIRE STANDARD TYPE
4" x 4" SQ x 2 1/8" DEEP J- BOX.
SET J-BOX EDGE AT ¼" BELOW FINISHED PANEL SURFACE
1. Connect Power Module AC wiring to main power lines in J-Box, using wire nuts or
connectors supplied.
Attach building ground wire to back box with screw provided.
2. Route wire nuts to side of J-box, insert Power Module into box and secure with 2 #8-32 box
screws. NOTE: Power module orientation is universal, position as required to clear nipple and
wire nuts in J-box.
3. For battery backup models, connect 2-pin polarized battery plug.
4. Run LED lamp plug from power module through canopy center and secure canopy to j-box
with 2 #8-32 screws supplied.
5. Raise sign to canopy, connect LED lamp plug, insert excess wiring and plug into j-box cavity.
Position lamp housing into canopy, center assembly, then secure with 2 #6-32 set screws.
BATTERY MODELS: BLACK: 120 277 VAC WHITE: Common
AC MODELS: Non- Polarized Line in.
WALL OR CEILING MOUNT
AC POWER
INPUT
120/277 VAC
POWER MODULE
MOUNT SCREWS
#8-32 (2 REQD)
SET SCREWS
#6-32
(2 REQD)
Crystal
Edge- lit LED
Sign System
Series CAE
Accessible Exit
Designed to meet requirements of State of Connecticut,
State Fire Safety Code Para 1011.1.1 and 1011.1.2
REV 01.12.02