18
TROUBLESHOOTING
The following items are the most common dispenser symptoms if problems occur. For
symptoms or remedies not shown, contact your Signode service representative for additional
information and details. The following dispenser symptoms are shown in this manual:
#1 SYMPTOM - Loose strap between idler wheels.
#2 SYMPTOM - Strap between dispenser and machine too loose following strapping cycle.
#3 SYMPTOM - Loose wraps on strap coil.
#4 SYMPTOM - Dispenser "Jerk" Stops.
#5 SYMPTOM - Dispenser "Jerk" Starts.
#6 SYMPTOM - Dancer arm swings upward with little or no resistance.
#1 SYMPTOM: Loose strap between idler wheels.
CAUSE
REMEDY
Dispenser brake improperly adjusted.
Adjust brake as required.
#2 SYMPTOM: Strap between dispenser and machine too loose following strapping cycle.
CAUSE
REMEDY
Dispenser brake improperly adjusted.
Adjust brake as required.
#3 SYMPTOM: Loose wraps on strap coil.
CAUSE
REMEDY
1.
Brake block pressure too low.
2.
Brake block friction surface worn out.
1.
Increase brake block pressure, See
brake adjustment procedure.
2.
Rotate brake block 180° to new friction
surface.
#4 SYMPTOM: Dispenser "Jerk" Stops.
CAUSE
REMEDY
Brake block pressure too high.
Reduce brake block pressure. See brake
adjustment procedure.
Summary of Contents for DF-2D
Page 1: ...DF 2D STRAP DISPENSER...
Page 9: ...9 BLANK...
Page 11: ...11 BLANK...
Page 14: ...14...
Page 15: ...15...
Page 16: ...16...