CLEARSCAPE MAIN INSTALLATION
CSFS / CSFM
SF - Slip Fitter Mount
Note: Tenon must be 3.75" or longer
.
Electrical Connection: (Not all options shown below are included.)
•
Connect the black fixture lead to the input voltage supply or Hot 1 (for 208/240V/480v
wiring).
•
Connect the white fixture lead to the neutral supply or Hot 2 (for 208/240V/480v wiring).
•
Connect the green or green/yellow ground lead to the incoming ground wire.
•
If Dimming is an option; connect the purple dimming positive lead to the supply
dimming positive lead.
•
If Dimming is an option; connect the grey dimming negative lead to the supply
dimming negative lead.
SF - Slip Fitter Mount
Note: Tenon must be 3.75" or longer.
(2) Splice Cover Screws
Splice Cover Screws
STEP 1:
Remove (2) splice cover screws and splice cover. To access wire
splice area.
STEP 2:
Route the supply wire through the tenon. Secure the supply wire to
keep from sliding back down the pole. Route wire through slip fitter
arm into splice area.
STEP 3:
Holding routed wires in splice area, carefully lower luminaire onto
tenon. Check to ensure that wires are not pinched between inside of
slip fitter and top of tenon and that luminaire and wires rotate freely.