page
443561208870 REV F
www.gardcolighting.com
CLEARSCAPE MAIN INSTALLATION
CSFS / CSFM
YK - Yoke Mount
STEP 1:
Mount yoke to surface with (2)-
1/2” bolts provided by others.
STEP 2:
Route the supplied cord to electrical junction box provided by
installer. Secure cord with connector.
STEP 3:
Make electrical connections per Electrical Connection section
inside junction box.
NOTE: Electrical Connections can be made after installation is
finished.
STEP 4: Replace junction box gasket and cover.
YK - Yoke Angle Adjustment
NOTE: Angle adjustment can be made before luminaire
installation.
STEP 1:
After the luminaire is installed, the vertical angle of the
luminaire can be adjusted up or down
STEP 2:
To adjust the angle, loosen the (2) 1/2
–13 X 1.25”
socket head cap bolts located in yoke arm. (Do remove
bolts.) Loosen only enough to allow rotation.
STEP 3:
Using the degree indicators, shown as a guide, rotate
the luminaire to the desired position and retighten the
bolt loosened in Step 2 to 75 ft.-lbs.
Adjustment Bolt and
aiming indicator lines
06/28/2021
4