5 of 8

2760 DryLoc pH/ORP Preamplifier

‡ SIGNET

The 2760-1/-2 Preamplifier can be connected to other manufacturer's instruments that can process the standard amplified mV signal for
pH and also are compatible with one of the temperature compensation devices available (3K

, PT1000, or 300

).

Refer to the manufacturer's manual for
wiring details.  Other products may
use different terms to identify the
function of each conductor.

Wiring from 2760 DryLoc Preamplifier to Other Manufacturer's Equipment

Wiring from 2760 DryLoc Connectors to Other Manufacturer's Equipment

Combination ORP (Redox) Electrodes
3-2775  (10K

 ID)

3-2777  (10K

 ID)

3-2775-1 (no Temp Comp)
3-2777-1 (no Temp Comp)
3-2755 (10K

 ID)

3-2757 (10K

 ID)

3-2757-WT (10K

 ID)

Combination pH Electrodes
3-2774 (3K

 RTD)

3-2776 (3K

 RTD)

3-2774-1 (PT1000 RTD)
3-2776-1 (PT1000 RTD)
3-2754 (PT1000 RTD)
3-2754-HF (PT1000 RTD)
3-2756 (PT1000 RTD)
3-2756-DI (PT1000 RTD)
3-2756-WT (PT1000 RTD)

Differential ORP (Redox)
Electrodes
3-2765-1 (10K

 ID)

3-2767-1 (10K

 ID)

3-2765-2 (PT1000 RTD)
3-2767-2 (PT1000 RTD)
3-2765-3 (300

Ω 

RTD)

3-2767-3 (300

Ω 

RTD)

Differential pH Electrodes
3-2764-1 (3K

 RTD)

3-2766-1 (3K

 RTD)

3-2764-2 (PT1000 RTD)
3-2766-2 (PT1000 RTD)
3-2764-3 (300

Ω 

RTD)

3-2766-3 (300

Ω 

RTD)

DryLoc Preamplifier

3-2760-1

3-2760-2

White (Temperature) 

Green (Temperature)

Blue (mV Reference)

Shield (Earth Ground)

Black (V-)

Red (V+)

Brown (Active mV, pH/ORP)

Combination ORP (Redox) Electrodes
3-2775  (10K

 ID)

3-2777  (10K

 ID)

3-2775-1 (no Temp Comp)
3-2777-1 (no Temp Comp)
3-2755 (10K

 ID)

3-2757 (10K

 ID)

3-2757-WT (10K

 ID)

Combination pH Electrodes
3-2774 (3K

 RTD)

3-2776 (3K

 RTD)

3-2774-1 (PT1000 RTD)
3-2776-1 (PT1000 RTD)
3-2754 (PT1000 RTD)
3-2754-HF (PT1000 RTD)
3-2756 (PT1000 RTD)
3-2756-DI (PT1000 RTD)
3-2756-WT (PT1000 RTD)

To any instrument with 
internal amplifier and 
matching temp device.

DryLoc Connector

3-2760-3

3-2760-4

White  RTD (Temperature) 

Green RTD (Temperature)

Blue Solution Ground 

Shield Earth Ground

Black Electrode Reference

Red (Active mV, pH/ORP)

Brown (no connection)

The 2760-3/4 Connectors can be used to interface other manufacturer's instruments to these +GF+ SIGNET DryLoc pH and ORP
electrodes.  The instrument must be able to process a standard mV signal from the pH or ORP electrode.  Several different temperature
devices are available.

Refer to the manufacturer's manual
for wiring details.  Other products
may use different terms to identify
the function of each conductor.

Main Contents

Previous View

pH/ORP Menu

Summary of Contents for DryLoc 2760

Page 1: ...terials CPVC Cable 4 6m 15 ft 3 cond shielded 22AWG Maximum cable 122 m 400 ft Shipping Weight 0 64 kg 1 41 lb Operating Temperature 0 C to 85 C 32 F to 185 F Storage Temperature 20 C to 85 C 4 F to 185 F Relative Humidity 0 to 95 non condensing without electrode connected Standards and Approvals CE Manufactured under ISO 9001 2000 for Quality and ISO 14001 1996 for Environmental Management Descri...

Page 2: ...the threads to secure the assembly 5 Use 3 4 in rigid or flexible conduit to protect the cable from damage 6 If the cable will be extended beyond the standard 15 ft supplied with the 2760 use a junction box to terminate the wires Note Do not extend the 2760 cable more than 120 m 400 ft In line Assembly and Installation 178 mm 7 in 107 mm 4 2 in 3 4 in Conduit customer supplied Fitting 2764 Differe...

Page 3: ... 4 in watertight pipe to the top of the 2760 Secure the threaded connection to prevent any leakage For additional defense against possible accumulation of condensation at the back seal area of the 2760 fill the lower 3 4 inches 75 100 mm of conduit or extension pipe with a flexible sealant such as silicone 2760 Submersible Sensor Assembly and Installation 94 mm 3 7 in 107 mm 4 2 in Fill with 3 to ...

Page 4: ... 2756 DI 3 2757 Standard Flat DryLoc 3 2754 3 2754 HF 3 2755 Connect this terminal to Earth GND to reduce electrical interference White Temp Green Temp Blue Iso Gnd Brown mV input Shield Black V Red V 12 11 10 9 8 7 6 5 18 17 16 15 14 13 12 11 16 15 14 13 12 11 10 9 3 8750 1 3 8750 2 3 8750 3 ProcessPro pH ORP Transmitter Any of these electrodes can be connected to the GF SIGNET ProPoint and Proce...

Page 5: ...RTD 3 2766 1 3KΩ RTD 3 2764 2 PT1000 RTD 3 2766 2 PT1000 RTD 3 2764 3 300Ω RTD 3 2766 3 300Ω RTD DryLoc Preamplifier 3 2760 1 3 2760 2 White Temperature Green Temperature Blue mV Reference Shield Earth Ground Black V Red V Brown Active mV pH ORP Combination ORP Redox Electrodes 3 2775 10KΩ ID 3 2777 10KΩ ID 3 2775 1 no Temp Comp 3 2777 1 no Temp Comp 3 2755 10KΩ ID 3 2757 10KΩ ID 3 2757 WT 10KΩ ID...

Page 6: ...6 of 8 2760 DryLoc pH ORP Preamplifier SIGNET Notes Main Contents Previous View pH ORP Menu ...

Page 7: ...7 of 8 2760 DryLoc pH ORP Preamplifier SIGNET Notes Main Contents Previous View pH ORP Menu ...

Page 8: ...process connection 3 2764 2 159 000 944 Differential pH Electrode PT1000 RTD 1 in NPT process connection 3 2764 3 159 000 945 Differential pH Electrode 300Ω RTD 1 in NPT process connection 3 2766 1 159 000 949 Differential pH Electrode 3KΩ RTD 1 in NPT process connection 3 2766 2 159 000 950 Differential pH Electrode PT1000 RTD 1 in NPT process connection 3 2766 3 159 000 951 Differential pH Elect...

Reviews: