Ordering Information

Mfr. Part No.

Code

Description

3-2760-1

159 000 939

Preamplifier with 3/4 in. NPT threads and 4.6 m (15 ft.) cable

3-2760-2

159 000 940

Preamplifier with 3/4 in. ISO threads and 4.6 m (15 ft.) cable

3-2760-3

159 000 941

Connector with 4.6 m (15 ft.) cable and 3/4 in. NPT threads

3-2760-4

159 000 942

Connector with 4.6 m (15 ft.) cable and ISO 7/1R 3/4 threads

Accessories and Replacement Parts

Calibration Tools
3-2759

159 000 762

pH/ORP System Tester (adapter cable sold separately)

3-2759.391

159 000 764

2759 Adapter Cable for use w/2760 DryLoc Preamplifier

3-0700.390

198 864 403

pH Buffer Kit (1 each 4, 7, 10 pH buffer in powder form, makes 50 mL)

5523-0624

159 000 636

Cable, 6 conductor, 24 AWG shielded

Mounting Hardware
3-8050-1

159 000 753

Universal Mount Junction Box

3-8052-1

159 000 755

3/4 in. NPT Mount Junction Box

3-9000.392-1

159 000 839

Liquid Tight Connector Kit, NPT (1 connector)

3-9000.392-2

159 000 841

Liquid Tight Connector Kit, PG13.5 (1 connector)

Electrodes

DryLoc pH Electrodes
3-2754

159 000 747

Combination pH Electrode, 3K

 RTD, flat glass

3-2754-HF

159 000 748

Combination pH Electrode, HF Resistsant, 3K

 RTD, flat glass

3-2756

159 000 750

Combination pH Electrode, 3K

 RTD, bulb glass

3-2756-DI

159 000 751

Combination pH Electrode, DI Resistant, 3K

  RTD, bulb glass

3-2764-1

159 000 943

Differential pH Electrode, 3K

 RTD, 1 in. NPT process connection

3-2764-2

159 000 944

Differential pH Electrode, PT1000 RTD, 1 in. NPT process connection

3-2764-3

159 000 945

Differential pH Electrode, 300

 RTD, 1 in. NPT process connection

3-2766-1

159 000 949

Differential pH Electrode, 3K

 RTD, 1 in. NPT process connection

3-2766-2

159 000 950

Differential pH Electrode, PT1000 RTD, 1 in. NPT process connection

3-2766-3

159 000 951

Differential pH Electrode, 300

 RTD, 1 in. NPT process connection

3-2774

159 000 955

Combo flat pH Electrode, 3K

 RTD, 3/4 in. NPT process connection

3-2774-1

159 000 956

Combo flat pH Electrode, PT1000 RTD, 3/4 in. NPT process connection

3-2776

159 000 959

Combo flat pH Electrode, 3K

 RTD, 3/4 in. NPT process connection

3-2776-1

159 000 960

Combo flat pH Electrode, PT1000 RTD, 3/4 in. NPT process connection

DryLoc ORP (Redox) Electrodes
3-2755

159 000 749

Combination ORP (Redox) Electrode, 10K

 ID, flat glass

3-2757

159 000 752

Combination ORP Electrode, 10 K

 ID, bulb glass

3-2765-1

159 000 946

Differential ORP (Redox) Electrode, 10K

 ID, 1 in. NPT process connection

3-2765-2

159 000 947

Differential ORP (Redox) Electrode, PT1000 RTD, 1 in. NPT process connection

3-2765-3

159 000 948

Differential ORP (Redox) Electrode, 300

 RTD, 1 in. NPT process connection

3-2767-1

159 000 952

Differential ORP (Redox) Electrode, 10K

 ID, 1 in. NPT process connection

3-2767-2

159 000 953

Differential ORP (Redox) Electrode, PT1000 RTD, 1 in. NPT process connection

3-2767-3

159 000 954

Differential ORP (Redox) Electrode, 300

 TC, 1 in. NPT process connection

3-2775

159 000 957

Combo flat ORP (Redox) Electrode, 10 K

 ID, 3/4 in. NPT process connection

3-2775-1

159 000 958

Combo flat ORP (Redox) Electrode, no Temp, 3/4 in. NPT process connection

3-2777

159 000 961

Combo bulb ORP (Redox) Electrode, 10 K

 ID, 3/4 in. NPT process connection

3-2777-1

159 000 962

Combo bulb ORP (Redox) Electrode, no Temp, 3/4 in. NPT process connection

Main Contents

Previous View

pH/ORP Menu

Summary of Contents for DryLoc 2760

Page 1: ...terials CPVC Cable 4 6m 15 ft 3 cond shielded 22AWG Maximum cable 122 m 400 ft Shipping Weight 0 64 kg 1 41 lb Operating Temperature 0 C to 85 C 32 F to 185 F Storage Temperature 20 C to 85 C 4 F to 185 F Relative Humidity 0 to 95 non condensing without electrode connected Standards and Approvals CE Manufactured under ISO 9001 2000 for Quality and ISO 14001 1996 for Environmental Management Descri...

Page 2: ...the threads to secure the assembly 5 Use 3 4 in rigid or flexible conduit to protect the cable from damage 6 If the cable will be extended beyond the standard 15 ft supplied with the 2760 use a junction box to terminate the wires Note Do not extend the 2760 cable more than 120 m 400 ft In line Assembly and Installation 178 mm 7 in 107 mm 4 2 in 3 4 in Conduit customer supplied Fitting 2764 Differe...

Page 3: ... 4 in watertight pipe to the top of the 2760 Secure the threaded connection to prevent any leakage For additional defense against possible accumulation of condensation at the back seal area of the 2760 fill the lower 3 4 inches 75 100 mm of conduit or extension pipe with a flexible sealant such as silicone 2760 Submersible Sensor Assembly and Installation 94 mm 3 7 in 107 mm 4 2 in Fill with 3 to ...

Page 4: ... 2756 DI 3 2757 Standard Flat DryLoc 3 2754 3 2754 HF 3 2755 Connect this terminal to Earth GND to reduce electrical interference White Temp Green Temp Blue Iso Gnd Brown mV input Shield Black V Red V 12 11 10 9 8 7 6 5 18 17 16 15 14 13 12 11 16 15 14 13 12 11 10 9 3 8750 1 3 8750 2 3 8750 3 ProcessPro pH ORP Transmitter Any of these electrodes can be connected to the GF SIGNET ProPoint and Proce...

Page 5: ...RTD 3 2766 1 3KΩ RTD 3 2764 2 PT1000 RTD 3 2766 2 PT1000 RTD 3 2764 3 300Ω RTD 3 2766 3 300Ω RTD DryLoc Preamplifier 3 2760 1 3 2760 2 White Temperature Green Temperature Blue mV Reference Shield Earth Ground Black V Red V Brown Active mV pH ORP Combination ORP Redox Electrodes 3 2775 10KΩ ID 3 2777 10KΩ ID 3 2775 1 no Temp Comp 3 2777 1 no Temp Comp 3 2755 10KΩ ID 3 2757 10KΩ ID 3 2757 WT 10KΩ ID...

Page 6: ...6 of 8 2760 DryLoc pH ORP Preamplifier SIGNET Notes Main Contents Previous View pH ORP Menu ...

Page 7: ...7 of 8 2760 DryLoc pH ORP Preamplifier SIGNET Notes Main Contents Previous View pH ORP Menu ...

Page 8: ...process connection 3 2764 2 159 000 944 Differential pH Electrode PT1000 RTD 1 in NPT process connection 3 2764 3 159 000 945 Differential pH Electrode 300Ω RTD 1 in NPT process connection 3 2766 1 159 000 949 Differential pH Electrode 3KΩ RTD 1 in NPT process connection 3 2766 2 159 000 950 Differential pH Electrode PT1000 RTD 1 in NPT process connection 3 2766 3 159 000 951 Differential pH Elect...