The power supply cable must not touch any hot parts and must be
positioned so that its temperature will not exceed 75
℃
at any point.
Check with an electrician whether the domestic wiring
system is suitable without alterations. Any alterations must
only be made by a qualified electrician.
-
If the cable is damaged or needs replacing, this should be done by
an after-sales technician using the proper tools, so as to avoid any
accidents.
-
If the appliance is being connected directly to the mains supply, an
omnipolar circuit-breaker must be installed with a minimum gap of
3mm between the contacts.
-
The installer must ensure that the correct electrical connection has
been made and that it complies with safety regulations.
-
The cable must not be bent or compressed.
-
The cable must be checked regularly and only replaced by a
proper qualified person.
EN
-
2
5
L1 L2 N1 N2 E
B
ro
w
n
B
la
c
k
B
lu
e
G
re
y
G
re
e
n
-Y
e
ll
o
w
L1 L2 N1 N2 E
B
ro
w
n
B
la
c
k
B
lu
e
G
re
y
G
re
e
n
-Y
e
ll
o
w
220 240V
~
380 415V
~
L
N
E
B
ro
w
n
B
lu
e
G
re
e
n
-Y
e
ll
o
w
220-240V
~
220-240V
~
220-240V
~