background image

6

Voltage Protection

The EG4 battery is designed to monitor the voltage of each individual cell and ensure that they
do not become overcharged or undercharged. It constantly measure the voltage and will ensure
that each cell does not exceed a specific voltage while charging, or go below another voltage
while discharging.

Current Protection

The EG4 will measure the current at all times, and has built in protections against exceeding
specific currents while charging or discharging. These include built in timers that will shut off
quickly in an event of an extremely large amount of current, and be delayed for a short period
when the current is only slightly over the allotted amount. This ensures that the battery shuts off
quickly when there is a possible short or other issue, and prevents the battery from turning off if
there is only a minor current spike that would not result in damage or unsafe conditions.

Integrated Communication

Each EG4 is built with the user in mind, and designed to show you as much information as
possible as easily as possible. We include an option to connect to your battery and software to
monitor the status of your battery. This allows you to see and understand exactly what your
battery is doing, as well as allowing you to troubleshoot if you run into any issues.

Battery Communications

The EG4 line of batteries from Signature Solar offer a communication system that you can
utilize in order to monitor your batteries remotely, as well as to communicate with compatible
inverters. This system will allow you to program your system for optimal performance, and to
further protect your investment by allowing you to make changes depending on how you plan to
use the battery. Signature Solar fully supports assisting customers who have purchased an EG4
battery and compatible battery on making sure this communication is configured correctly.
Additionally, we have provided downloadable software from our website that can be installed on
a local computer and allow you to manage your battery or make changes directly. This software
can be located on our website at (

https://www.signaturesolar.us

). We strongly recommend

watching our videos on how to configure this software. If you have any questions or trouble
while setting up your communication, please contact our customer service team for further
assistance. As a general guide, we have included step by step directions below that will work
with most systems.

1. Looking at the front of your battery, you will see 4 RS485 ports (these look like ethernet

ports).

2. To connect to your inverter, you will use the CAN or RS485 port. To connect to a

computer, you will use the RS485 port. To connect between batteries, you will use the
BATTERY COMM port. Insert the plug into the desired port.

3. Connect the other end of your communication cable to the device you are connecting to.

When connecting, ensure the main battery has the right dipswitch settings. For EG4-LLs,
this will be (Down, Down, Down, Up).

Summary of Contents for EG4-LL

Page 1: ... an EG4 LL battery in the past you will find this manual to be a useful reference tool Table of Contents What Is Included With Your Purchase 2 What Tools Are Needed For Installation 2 How To Connect Cables To Your Terminals 2 Connecting The Batteries In Parallel 3 Why connect in parallel 3 How do you wire your batteries in parallel 3 Connecting The Batteries In Series 4 Why connect in series 4 How...

Page 2: ...lor coded red for positive and black for negative 2 Verify you have all finishing hardware to attach the cable properly Check to ensure the bolt insert for the terminal fully seats and can be tightened to the proper torque 3 Connect the cables to your battery terminals by removing the terminal bolts inserting them through the eyelet of the proper cable and reseating the bolt into the terminal bloc...

Page 3: ... short circuits 1 Identify the positive and negative terminals on your batteries These are color coded red for positive and black for negative for your convenience 2 Make a proper connection to the positive terminal of your first battery Ensure that you have followed directions to properly connect the cable to the terminal Improper connections can cause severe damage and may void your warranty 3 C...

Page 4: ...h a proper lithium charger to ensure they are at the same voltage 1 Identify the positive and negative terminals on your batteries These are color coded red for positive and black for negative for your convenience 2 Make a proper connection to the negative terminal of your first battery Ensure that you have followed directions to properly connect the cable to the terminal Improper connections can ...

Page 5: ...battery can be found after the definitions listed below The BMS includes the following protections PCB Temperature Protection The PCB Temperature Protection of the BMS will ensure that the PCB does not overheat The PCB is the Printed Circuit Board much like a motherboard on a computer This is the part that contains most of the brains of your battery Much like a computer has fans and other cooling ...

Page 6: ...ommunication system that you can utilize in order to monitor your batteries remotely as well as to communicate with compatible inverters This system will allow you to program your system for optimal performance and to further protect your investment by allowing you to make changes depending on how you plan to use the battery Signature Solar fully supports assisting customers who have purchased an ...

Page 7: ... Environmental Factors The environment you store your EG4 battery in can greatly affect the health of the battery The temperature should remain temperate Exact temperature specifications can be located at the end of the manual We also suggest keeping the battery away from locations where it may get wet or locations with extremely high humidity What steps should you take to maintain a healthy batte...

Page 8: ...n or entity All BMS and Cell Exchanges are covered throughout the warranty period If a full replacement warranty is needed the warranty is prorated 1 9th per year after the first year at the current retail pricing Warranty Exclusions Signature Solar has no obligation under this limited warranty for product subjected to the following conditions including but not limited to Damages incurred during i...

Page 9: ... or the transactions relating to its subject matter All installation advice provided by Signature Solar before during or after purchase of solar equipment is purely for the purpose of general concept education and must not replace the expertise of a licensed and trained solar specialist The Customer agrees to full indemnification for Signature Solar henceforth from any legal recourse relating to a...

Page 10: ...10 Battery Specifications Battery Parameters ...

Page 11: ...11 Battery Module Performance Curve ...

Reviews: