- 28 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE.
All rights reserved. Only training and service purposes.
- 28 -
RRefrigerator Sensor Error (S1/S2/S3)
Is the Connector disconnected
or loose between Main PCB and
sensor?
Check the Sensor resistance.
Is resistance 0Ω (Sensor short)?
Check the Sensor resistance.
Is resistance OFF (Sensor open)?
Change the
Sensor
Go to 6
Explain to customer
Check the sensor connection.
Is the sensor connection normal?
Reconnect or repair
the connector
Reconnect
or repair the
connector
Change the
Sensor
Replace the
refrigerator
CON202
[S1]1 pin&3pin
[S2]9 pin&11pin
[S3]17 pin&19pin
Resistance [Ω]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Check the Temperature and
resistance refer to the table.
No problem?
CON202
1
4
2
3
5
6
7
Summary of Contents for SKSCW181RP
Page 82: ......