- 14 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE.
All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(1) FCT0 Trip and LED Blinking 1 time (FCT0 Fault)
→ Purpose : To detect the compressor voltage and current sensing error.
→ Restart every 30 seconds after compressor off.
Blink
Blink
OFF
OFF
LED 1 Blinks
Replace PCB
LED
1 Blinks
About 5min
Reset
Test Mode
1 Input