- 13 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE.
All rights reserved. Only training and service purposes.
2. Simple Check Flow Chart
- Not Cooling (LED Blinking)
- Not Cooling (LED No Blinking)
Check Comp.
Y
N
PCBA
Output
> 60V?
N
N
Y
LED
7 Blinks
LED
2 Blinks
LED
1 Blinks
Replace PCB
Comp.
Action?
Replace PCB
Y
LED6 Blinks
Comp.
Action?
Harness
wiring?
Y
Repair Harness
N
LED
8 Blinks
Replace PCB
Reset
LED
7 Blinks
LED
1 Blinks
LED
2 Blinks
LED
6 Blinks
LED
8 Blinks
LED
3 Blinks
LED
3 Blinks
LED
5 Blinks
Comp.
Action?
LED
5 Blinks
Check C
omp.
Check Comp.
Check
Cycle leakage
Cycle
Cycle leakage
Check
Cycle leakage
About 5min
About 5min
About 5min
About 5min
About 5min
About 5min
About 5min
LED
4 Blinks
Replace PCB
LED
4 Blinks
About 5min
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
Test Mode
1 Input
PCBA
Output
> 60V
Replace PCB
Replace PCB
Y
N
Y
N
LED Trip Information
1
Current/Voltage Sensing Error
2
Over Stroke
3
Comp Connection Error
4
Over Voltage Error
5
Comp Lock Error
6
Over Current Error
7
IPM Error
8
Communication Error
Comp.
Action?
PCBA
Output
> 60V
Replace PCB
N
N
Test Mode
1 Input
About 5min
Summary of Contents for SKSCW181RP
Page 82: ......