CSTO 082
C-DIAS SAFETY-DIGITAL OUTPUT MODULE
Page 14
31.01.2018
Safety Conformity
Conformity with EU Standards
The module has been designed in accordance with the following European Union direc-
tives:
2006/42/EG
Machinery Directive
2014/30/EU
EMC Directive
2011/65/EU
RoHS Directive
Functional safety standards
-
EN/IEC 62061
SIL 3 or SIL CL 3
-
EN ISO 13849
PL e / Cat. 4
Configuration: 2-channel redundant (diverse)
Safety parameters
Diagnostic coverage
DC [%]
95.94
Probability of failure per hour
PFH
D
[1/h]
7.05E-09
Mean time to dangerous failure
MTTFd [years] symmetrized
351
Proof Test Interval [years]
20
Table 5: Safety parameters
Please note:
The parameters shown are only applicable with the simultaneous parallel use of
two inputs.