background image

SL-50  SL-60 MIXERS 

15 of 23

PERIODICAL MAINTENANCE. 

 
DAILY CLEANING AND CONTROL OPERATIONS: 

 

Cleaning outside surfaces of the bowl and tools with cloth and neutral degreasing agent. 

 

Operative and emergency controls check.  

 

 
MONTHLY, ANNUAL MAINTENANCE OPERATIONS 
 

 
 
Monthly maintenance:  

 

Thorough cleaning of the mixer. 

 

Operative and emergency controls functioning check. 

 

Mixer's external components' check: tools, bowl, protective grid. 

 Transmission 

noise 

check. 

 
Annual maintenance: 

 

Thorough cleaning and check of entire machinery. 

 

Thorough check of transmission organs. 

 

Bolt tightening check for entire machinery. 

 
Bolt tightening torques. 

 M6 

M8 

M10 

M12 

M14 

M16 

Mixer screws (8.8) [Nm]  

9.7 

23 

47 

80 

130 

196 

Stop rod screws (10.9) [Nn] 

13.6 

33 

113 

180 

275 

 

 

ƒ

 

Installed safety systems check.  

 

 
SPARE PARTS 

SIGMA S.r.l. reserves the right to carry out all the modifications that it deems necessary for its mixer 
models. It is therefore always necessary to specify: 

 

Type of mixer 

 Serial 

number 

 

Year of construction 

 

Position, description, item code and desired amount of pieces requested. 

 
Send the request to:  
 
MAIN COMPONENTS: 
 

 

Raw materials used: almost all of the components of the mixer are made of steel, cast iron, brass 
and plastic. All of these components can be disposed of easily and do not represent a danger for 
environmental pollution and/or personal safety. Separate the different materials for subsequent 
reuse or differentiated waste collection.  

 

The electrical system must be dismantled and disposed of through a specialised company.  

 

Treatment of surfaces: painting of metallic surfaces with products compatible for food use. 

 

Sigma packaging replies fully with that required by Directive 94/62/EC and by Legislative Decree 
05/02/97 n. 22 (and subsequent amendments and integrations). They thus can easily be assimilated 
with city waste and can be inserted in any public differentiated waste program. 

 
DISMANTLING AND WASTE DISPOSAL:   
The purchaser is responsible for putting the mixer out of service, who must comply with local standards and 
regulations. Dismantling of mechanical and electrical parts must be entrusted to competent personnel. 
 

Summary of Contents for Silver 50

Page 1: ...SL 50 SL 60 MIXERS 1 of 23 USE AND MAINTENANCE INSTRUCTION MANUAL FOR 50 60 SILVER AND GREENLINE MIXER MACHINE...

Page 2: ...he whole life of the machine INDEX SAFETY INSTRUCTIONS 3 RESIDUAL RISKS 3 RESIDUAL RISKS PROHIBITIONS OBLIGATIONS Summarised table 4 SYMBOLS USED AND QUALIFICATIONS OF THE PERSONNEL 4 USE AND DESCRIPT...

Page 3: ...onditions and clean it with a neutral degreasing agent i e with Marseille soap Safety devices The mixer is equipped with some devices which protect its operation as well as the safety of the operator...

Page 4: ...ead and understood the use and maintenance manual PERSON IN CHARGE OF HANDLING ZIONE Person in good health who due to qualification job or experience is qualified to carry out handling of loads and wh...

Page 5: ...ter switch lift the grid and remove it from the bowl by hand Use a plastic aluminium or wooden spatula which do not scratch the bowl to make the operation easier CONDITIONS FOR USE Atmospheric conditi...

Page 6: ...pallet Cardboard pallet Wooden cage or crate Model AxBxH cm Weight kg AxBxH cm Weight kg AxBxH cm Weight kg Silver 50 60 1000x650x1350 215 1000x650x1400 225 1000x650x1500 230 240 TRANSPORTATION AND H...

Page 7: ...se to the ground as possible Use the required P P E The mixer inclines by 8 10 degrees when lifted Transport standards of the mixer with wheels Act on an empty area and on a floor with adequate sturdi...

Page 8: ...always tighten the two supports A until the wheels are fully lifted Connection to electrical mains The electrical connection must be carried out by a specialised electrician according to the modalitie...

Page 9: ...xer is provided with a master switch on the right side It is controlled by one of the front panels shown below The first panel has a manual timer with a selector for inversion of the rotation directio...

Page 10: ...IMERS MANUAL SWITCH TO BE TURNED IN THE EVENT THE TIMERS ARE FAULTY EMERGENCY FIRST AND SECOND SPEED INVERSION OF ROTATION DIRECTION OF THE BOWL FOR A LIMITED PERIOD OF TIME START KEY FIRST SPEED TIME...

Page 11: ...ng submitted to improper use The limit of use of the mixer is reached not by exceeding on the amount of the pasta limited by the volume of the bowl but by the too low percentage of water A first but v...

Page 12: ...rotection board Safety micro switch of grid Purpose stop the machine temporarily Function by lifting the protection grid the motor power supply interrupts temporarily stopping the machine To reset the...

Page 13: ...machine Should a power cable be damaged replace it with a H07RN F cable with a 3x1 5 mm2 section Cleaning the mixer is not jet proof Do not wash it with running water Clean it with a moist cloth and...

Page 14: ...opriate register B until the correct tension is reached The tensioning of the secondary transmission causes tension variations of the primary transmission that must be registered again Tensioning of t...

Page 15: ...umber Year of construction Position description item code and desired amount of pieces requested Send the request to MAIN COMPONENTS Raw materials used almost all of the components of the mixer are ma...

Page 16: ...SL 50 SL 60 MIXERS 16 of 23 SL 50 STANDARD VERSION SPARE PARTS LIST...

Page 17: ...ock Safety micro switch 14 03173098 03173097 Silver 50 1 1 Mobile mixture guard Fixed mixture guard 15 01173039 04173040 Silver 50 1 Plate Bowl 50 Kg 16 01173057 Silver 50 1 Stop rod 17 01173041 Silve...

Page 18: ...SL 50 SL 60 MIXERS 18 of 23 SL 50 GREEN LINE VERSION SPARE PARTS LIST...

Page 19: ...173098 03173097 Silver 50 1 1 Mobile mixture guard Fixed mixture guard 15 01173039 04173040 Silver 50 1 Plate Bowl 50 Kg 16 01173057 Silver 50 1 Stop rod 17 01173041 Silver 50 2 Spiral 18 01173032 Sil...

Page 20: ...SL 50 SL 60 MIXERS 20 of 23 ELECTRICAL LAYOUT STANDARD VERSION...

Page 21: ...SL 50 SL 60 MIXERS 21 of 23 ELECTRICAL LAYOUT GREEN LINE VERSION...

Page 22: ...tached 1 Check connection Pressing the run button the mixer does not start 1 The protection grid is open 2 Safety micro switches anomalies 1 Rotate it and reposition it in closed position 2 Replace th...

Page 23: ...other waste Differentiated waste collection of this appliance having reached the end of its life is organised and managed by the manufacturer The user who desires to dispose of the present appliance...

Reviews: