S1 CONFIGURATION

COMM PANEL ADDRESS

Whenever there are multiple control panels in a system, such as SYX or SBX control panels,

the LOGICAL ADDRESS for each panel must be different. There are 64 possible addresses that
the COMM port can access. These addresses are set using S1,1-6 which are accessed through
the rear of the control panel. The COMM panel address table is shown below.

AUTOTAKE

S1-7 the AUTOTAKE function of the SBX-32.  When the AUTOTAKE function is enabled, the

TAKE request will automatically be generated whenever a valid input is selected.

NOTE: Before any changes in the switch settings take effect, the panel must be reset by removing
and restoring power.

SBX-32 COMM PANEL ADDRESS

ADDRESS

S1,1

S1,2

S1,3

S1,4

S1,5

S1,6

   1

 OFF

 OFF

 OFF

 OFF

 OFF

 ON

   2

 OFF

 OFF

 OFF

 OFF

 ON

 OFF

   3

 OFF

 OFF

 OFF

 OFF

 ON

 ON

   4

 OFF

 OFF

 OFF

 ON

 OFF

 OFF

   5

 OFF

 OFF

 OFF

 ON

 OFF

 ON

   6

 OFF

 OFF

 OFF

 ON

 ON

 OFF

   7

 OFF

 OFF

 OFF

 ON

 ON

 ON

   8

 OFF

 OFF

 ON

 OFF

 OFF

 OFF

   9

 OFF

 OFF

 ON

 OFF

 OFF

 ON

  10

 OFF

 OFF

 ON

 OFF

 ON

 OFF

  11

 OFF

 OFF

 ON

 OFF

 ON

 ON

  12

 OFF

 OFF

 ON

 ON

 OFF

 OFF

  13

 OFF

 OFF

 ON

 ON

 OFF

 ON

  14

 OFF

 OFF

 ON

 ON

 ON

 OFF

  15

 OFF

 OFF

 ON

 ON

 ON

 ON

  16

 OFF

 ON

 OFF

 OFF

 OFF

 OFF

  17

 OFF

 ON

 OFF

 OFF

 OFF

 ON

  18

 OFF

 ON

 OFF

 OFF

 ON

 OFF

  19

 OFF

 ON

 OFF

 OFF

 ON

 ON

  20

 OFF

 ON

 OFF

 ON

 OFF

 OFF

  21

 OFF

 ON

 OFF

 ON

 OFF

 ON

  22

 OFF

 ON

 OFF

 ON

 ON

 OFF

  23

 OFF

 ON

 OFF

 ON

 ON

 ON

  24

 OFF

 ON

 ON

 OFF

 OFF

 OFF

  25

 OFF

 ON

 ON

 OFF

 OFF

 ON

  26

 OFF

 ON

 ON

 OFF

 ON

 OFF

  27

 OFF

 ON

 ON

 OFF

 ON

 ON

  28

 OFF

 ON

 ON

 ON

 OFF

 OFF

  29

 OFF

 ON

 ON

 ON

 OFF

 ON

  30

 OFF

 ON

 ON

 ON

 ON

 OFF

  31

 OFF

 ON

 ON

 ON

 ON

 ON

  32

 ON

 OFF

 OFF

 OFF

 OFF

 OFF

NOTE: Before any changes in the switch settings take effect, the panel must be reset by removing and restoring power.

Summary of Contents for SBX-32

Page 1: ...SBX 32 SINGLE BUS CONTROL PANEL OPERATOR S MANUAL SIGMA ELECTRONICS INC 1027 COMMERCIAL AVENUE EAST PETERSBURG PA 17520 717 569 2681 P O Box 448 ...

Page 2: ...ol panel are four LEVEL buttons This allows selection of any one of the four levels When no LEVEL button has been selected the panel is operating in a FOLLOW mode A single momentary press of the desired level button activates a LEVEL that causes the respective display to go blank This operation will allow a BREAKAWAY where only one level is changed or a SPLIT where multiple levels select different...

Page 3: ...em with the SCI or the COMM line The selected OUTPUT of the control panel can be reviewed by pressing the TAKE key The OUTPUT will be displayed in the LEVEL 4 window for 2 seconds This must be done when there are no preset conditions AUTOTAKE The panel is also capable of switching without the use of the TAKE switch This is accomplished by setting DIP switch S1 7 to ON at the rear of the control pa...

Page 4: ...2 S1 3 S1 4 S1 5 S1 6 1 OFF OFF OFF OFF OFF ON 2 OFF OFF OFF OFF ON OFF 3 OFF OFF OFF OFF ON ON 4 OFF OFF OFF ON OFF OFF 5 OFF OFF OFF ON OFF ON 6 OFF OFF OFF ON ON OFF 7 OFF OFF OFF ON ON ON 8 OFF OFF ON OFF OFF OFF 9 OFF OFF ON OFF OFF ON 10 OFF OFF ON OFF ON OFF 11 OFF OFF ON OFF ON ON 12 OFF OFF ON ON OFF OFF 13 OFF OFF ON ON OFF ON 14 OFF OFF ON ON ON OFF 15 OFF OFF ON ON ON ON 16 OFF ON OFF ...

Page 5: ...ON 42 ON OFF ON OFF ON OFF 43 ON OFF ON OFF ON ON 44 ON OFF ON ON OFF OFF 45 ON OFF ON ON OFF ON 46 ON OFF ON ON ON OFF 47 ON OFF ON ON ON ON 48 ON ON OFF OFF OFF OFF 49 ON ON OFF OFF OFF ON 50 ON ON OFF OFF ON OFF 51 ON ON OFF OFF ON ON 52 ON ON OFF ON OFF OFF 53 ON ON OFF ON OFF ON 54 ON ON OFF ON ON OFF 55 ON ON OFF ON ON ON 56 ON ON ON OFF OFF OFF 57 ON ON ON OFF OFF ON 58 ON ON ON OFF ON OFF ...

Page 6: ... is to be controlled SOURCE GROUP S2 1 S2 2 1 32 OFF OFF 32 64 OFF ON 65 96 ON OFF 97 128 ON ON SBX 32 OUTPUT ADDRESS OUTPUT S2 3 S2 4 S2 5 S2 6 S2 7 S2 8 S2 9 1 OFF OFF OFF OFF OFF OFF ON 2 OFF OFF OFF OFF OFF ON OFF 3 OFF OFF OFF OFF OFF ON ON 4 OFF OFF OFF OFF ON OFF OFF 5 OFF OFF OFF OFF ON OFF ON 6 OFF OFF OFF OFF ON ON OFF 7 OFF OFF OFF OFF ON ON ON 8 OFF OFF OFF ON OFF OFF OFF 9 OFF OFF OFF...

Page 7: ...FF ON ON OFF ON 46 OFF ON OFF ON ON ON OFF 47 OFF ON OFF ON ON ON ON 48 OFF ON ON OFF OFF OFF OFF 49 OFF ON ON OFF OFF OFF ON 50 OFF ON ON OFF OFF ON OFF 51 OFF ON ON OFF OFF ON ON 52 OFF ON ON OFF ON OFF OFF 53 OFF ON ON OFF ON OFF ON 54 OFF ON ON OFF ON ON OFF 55 OFF ON ON OFF ON ON ON 56 OFF ON ON ON OFF OFF OFF 57 OFF ON ON ON OFF OFF ON 58 OFF ON ON ON OFF ON OFF 59 OFF ON ON ON OFF ON ON 60 ...

Page 8: ... ON ON 100 ON ON OFF OFF ON OFF OFF 101 ON ON OFF OFF ON OFF ON 102 ON ON OFF OFF ON ON OFF 103 ON ON OFF OFF ON ON ON 104 ON ON OFF ON OFF OFF OFF 105 ON ON OFF ON OFF OFF ON 106 ON ON OFF ON OFF ON OFF 107 ON ON OFF ON OFF ON ON 108 ON ON OFF ON ON OFF OFF 109 ON ON OFF ON ON OFF ON 110 ON ON OFF ON ON ON OFF 111 ON ON OFF ON ON ON ON 112 ON ON ON OFF OFF OFF OFF 113 ON ON ON OFF OFF OFF ON 114 ...

Page 9: ...s for the COMM input signal comparator The direction of the COMM line is controlled by P3 7 and is normally in the receive mode except when a panel transaction is made U2 provides the reset function to the microprocessor upon three different conditions The first is a power on reset The second is at any time the 5 VDC power supply goes below 4 5 VDC a brownout condition Third is when the microproce...

Reviews: