4
S1 CONFIGURATION
COMM PANEL ADDRESS
Whenever there are multiple control panels in a system, such as SYX or SBX control panels,
the LOGICAL ADDRESS for each panel must be different. There are 64 possible addresses that
the COMM port can access. These addresses are set using S1,1-6 which are accessed through
the rear of the control panel. The COMM panel address table is shown below.
AUTOTAKE
S1-7 the AUTOTAKE function of the SBX-32. When the AUTOTAKE function is enabled, the
TAKE request will automatically be generated whenever a valid input is selected.
NOTE: Before any changes in the switch settings take effect, the panel must be reset by removing
and restoring power.
SBX-32 COMM PANEL ADDRESS
ADDRESS
S1,1
S1,2
S1,3
S1,4
S1,5
S1,6
1
OFF
OFF
OFF
OFF
OFF
ON
2
OFF
OFF
OFF
OFF
ON
OFF
3
OFF
OFF
OFF
OFF
ON
ON
4
OFF
OFF
OFF
ON
OFF
OFF
5
OFF
OFF
OFF
ON
OFF
ON
6
OFF
OFF
OFF
ON
ON
OFF
7
OFF
OFF
OFF
ON
ON
ON
8
OFF
OFF
ON
OFF
OFF
OFF
9
OFF
OFF
ON
OFF
OFF
ON
10
OFF
OFF
ON
OFF
ON
OFF
11
OFF
OFF
ON
OFF
ON
ON
12
OFF
OFF
ON
ON
OFF
OFF
13
OFF
OFF
ON
ON
OFF
ON
14
OFF
OFF
ON
ON
ON
OFF
15
OFF
OFF
ON
ON
ON
ON
16
OFF
ON
OFF
OFF
OFF
OFF
17
OFF
ON
OFF
OFF
OFF
ON
18
OFF
ON
OFF
OFF
ON
OFF
19
OFF
ON
OFF
OFF
ON
ON
20
OFF
ON
OFF
ON
OFF
OFF
21
OFF
ON
OFF
ON
OFF
ON
22
OFF
ON
OFF
ON
ON
OFF
23
OFF
ON
OFF
ON
ON
ON
24
OFF
ON
ON
OFF
OFF
OFF
25
OFF
ON
ON
OFF
OFF
ON
26
OFF
ON
ON
OFF
ON
OFF
27
OFF
ON
ON
OFF
ON
ON
28
OFF
ON
ON
ON
OFF
OFF
29
OFF
ON
ON
ON
OFF
ON
30
OFF
ON
ON
ON
ON
OFF
31
OFF
ON
ON
ON
ON
ON
32
ON
OFF
OFF
OFF
OFF
OFF
NOTE: Before any changes in the switch settings take effect, the panel must be reset by removing and restoring power.